Reference. 1026363048

BD Vacutainer Plus Sodium Citrate Tubes 2.7 ml 13 x 75 mm Sterile. Buffered Citrate 0.109 M. Box of 100 units.

Vacuum blood extraction tube. Made of plastic (Polypropylene)

Sterile and for single use

These tubes are recommended for plasma coagulation studies.

They contain a solution of buffered trisodium citrate, as an anticoagulant.

0.109M: 3.2% sodium citrate + citric acid

pH = 5.2

The blood/additive...

Personalized attention
Personal advice
BD Vacutainer Plus Sodium Citrate Tubes 2.7 ml 13 x 75 mm Sterile. Buffered Citrate 0.109 M. Box of 100 units.
BD Vacutainer Plus Sodium Citrate Tubes 2.7 ml 13 x 75 mm Sterile. Buffered Citrate 0.109 M. Box of 100 units.
26,41€ (31,96€ VAT INCLUDED)
Buy
Secure payment
Approximate delivery time 3 to 7 days

Description

BD

Vacuum blood extraction tube. Made of plastic (Polypropylene)

Sterile and for single use

These tubes are recommended for plasma coagulation studies.

They contain a solution of buffered trisodium citrate, as an anticoagulant.

0.109M: 3.2% sodium citrate + citric acid

pH = 5.2

The blood/additive ratio is 9:1

The results are clinically equivalent to the globally recognized "Gold Standard", the full-fill glass tube with buffered citrate BD Vacutainer™ of 4.5 ml.

They are clinically tested in multicenter clinical trials for routine coagulation tests with the main patient populations (normal patients, patients under treatment with oral anticoagulant warfarin and patients under therapy with unfractionated heparin) and have been evaluated with the most used autoanalyzers in coagulation tests.

The innovative geometry of the tube minimizes the "free space" and the platelet activation associated with it, optimizing the monitoring of the aPTT of patients treated with unfractionated heparin. They are full-fill tubes with the external dimensions of a standard 13x75mm tube and with small fill volumes (2.7ml and 1.8ml).

Benefits:

Preserves coagulation factors

It is the most recommended for coagulation studies

Prevents pH variations that could modify the results

Prevents platelet activation, improving the accuracy of results and reducing the risk of misclassification of patients under unfractionated heparin therapy.

Compatible with tube holders and autoanalyzers. It improves the workflow of the laboratory.

Facilitates the opening of the tube. It prevents the adherence of erythrocytes. It prevents the onset of latex allergies.

With its design, it prevents direct contact with the micro drop of blood that remains in the cap, after extraction. It prevents the splash and dispersion of serum drops during its opening.

Alternative products