Reference. 10977800010
Multiparameter Monitor PC-900 Plus (NIBP, PR, SpO2)
Multiparameter Monitor PC-900 Plus (NIBP, PR, SpO2)
Personal advice
Description
Vital Signs Monitor for the continuous monitoring of Non-Invasive Blood Pressure (NIBP), Pulse Rate (PR) and Oximetry (SpO2).
Features:
•7" touch screen with wave graph and numerical values of SpO2/ECG
•Tall design for comfortable and pleasant use
•Memory of up to 12000 groups of NIBP, 3000 groups of SpO2 and alarms
•Historical data can be reviewed as waves, list or trend charts
•Data export and software update via USB
•Available SpO2 compatible with Nellcor, Pani SunTech and Tympanic Thermometer
•Power supply 100-240 Vac, 50/60 Hz
•Internal Lithium-Ion battery 11.1V/4400 mAh
NIBP (NIBP)
-Method: Oscillometric
-Accuracy of measurement:
Max. average deviation: ±5 mmHg
Max. average deviation: 8 mmHg
-Systolic pressure:
Adult: 40 mmHg-275 mmHg
Pediatric: 40 mmHg-200 mmHg
Neonate: 40 mmHg-135 mmHg
-Diastolic pressure:
Adult: 10 mmHg-210 mmHg
Pediatric: 10 mmHg-150 mmHg
Neonate: 10 mmHg-95 mmHg
-Mean arterial pressure:
Adult: 20 mmHg-230 mmHg
Pediatric: 20 mmHg-165 mmHg
Neonate: 20 mmHg-110 mmHg
-Measurement modes: Manual, Auto, STAT
-Overpressure protection limit:
Adult: 300 mmHg
Pediatric: 240 mmHg
Neonate: 150 mmHg
SpO2
-Transducer: Led dual wavelength
-SpO2 Measurement range: 35%-100%
-SpO2 Measurement accuracy Low perfusion level: 3% between 70% up to 100% Less than 0.4%
PR (HR)
-Measurement range 30lpm – 240lpm
-Measurement accuracy ±2%
Features:
•7" touch screen with wave graph and numerical values of SpO2/ECG
•Tall design for comfortable and pleasant use
•Memory of up to 12000 groups of NIBP, 3000 groups of SpO2 and alarms
•Historical data can be reviewed as waves, list or trend charts
•Data export and software update via USB
•Available SpO2 compatible with Nellcor, Pani SunTech and Tympanic Thermometer
•Power supply 100-240 Vac, 50/60 Hz
•Internal Lithium-Ion battery 11.1V/4400 mAh
NIBP (NIBP)
-Method: Oscillometric
-Accuracy of measurement:
Max. average deviation: ±5 mmHg
Max. average deviation: 8 mmHg
-Systolic pressure:
Adult: 40 mmHg-275 mmHg
Pediatric: 40 mmHg-200 mmHg
Neonate: 40 mmHg-135 mmHg
-Diastolic pressure:
Adult: 10 mmHg-210 mmHg
Pediatric: 10 mmHg-150 mmHg
Neonate: 10 mmHg-95 mmHg
-Mean arterial pressure:
Adult: 20 mmHg-230 mmHg
Pediatric: 20 mmHg-165 mmHg
Neonate: 20 mmHg-110 mmHg
-Measurement modes: Manual, Auto, STAT
-Overpressure protection limit:
Adult: 300 mmHg
Pediatric: 240 mmHg
Neonate: 150 mmHg
SpO2
-Transducer: Led dual wavelength
-SpO2 Measurement range: 35%-100%
-SpO2 Measurement accuracy Low perfusion level: 3% between 70% up to 100% Less than 0.4%
PR (HR)
-Measurement range 30lpm – 240lpm
-Measurement accuracy ±2%