Reference. 94278K15-ETCO2C-12
K15 multiparameter monitor with 15" touch screen (EtCO2, ECG, NIBP, PR, TEMP, RESP, SpO2)
Multifunctional patient monitor ideal for monitoring the vital physiological signs of adult, pediatric, and neonatal patients.
Description
Multifunctional patient monitor ideal for monitoring the vital physiological signs of adult, pediatric and neonatal patients.
Features:
- Real-time recording and visualization of the following parameters:
• ECG
• Non-invasive blood pressure (NIBP/PANI)
• Heart rate (PR/RC)
• Oxygen saturation (SpO2)
• Respiration (RESP)
• Temperature (TEMP)
• Exhaled carbon dioxide (EtCO2)
Product characteristics:
- Ergonomic design.
- With intuitive user interface.
- USB port for data transfer and software update.
- 9 waveform traces on the screen.
- Windos style screen view - easy to use.
- Visual and audible alarm for physiological and technical alarms.
- Large capacity storage.
- Suitable for use with original Nellcor sensors.
- Has a protection against defibrillator discharge.
- Equipped with resistance against interference from the electrosurgical apparatus.
- Detection and inhibition of cardiac pacemaker pulse.
- Internal software: GB, DE, FR, PT, ES, IT, PL, TR, RU
- PC software GB, IT, ES.
- Compatible with Windows XP, 7, 8, 10, 11.
Technical specifications:
- ECG input dynamic range: ±(0.5~5 mVp).
- Differential input impedance: =10 MO.
- Bandwidth:
• 0.05~150 Hz (diagnosis)
• 0.5~40 Hz (monitoring)
• 1~20 Hz (operation)
- CMRR: =90 dB ( Diagnosis) / =105 dB (Monitoring and operation).
- Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and automatic sweep speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s.
- HR measurement range: 15~350 bpm ±1% or ±2 bpm, whichever is greater.
- Pacemaker pulse detection and rejection function.
RESP:
- Measurement range: 0~120 rpm ±5% or ±2 rpm, whichever is greater.
TEMP:
- Measurement range: 21.0~50.0 °C ±0.2 °C from 25~45 °C.
NIBP (PANI):
- Technique: oscillometric method.
- Typical measurement time: <30 seconds (adult cuff).
- NIBP measurement range:
• SYS: 40~275 mmHg (adult) / 40~200 mmHg (pediatric) / 40~135 mmHg (neonate).
• DIA: 10~210 mmHg (adult) / 10~150 mmHg (pediatric) / 10~95 mmHg (neonate).
• MAP: 20~230 mmHg (adult) / 20~165 mmHg (pediatric) / 20~110 mmHg (neonate).
- NIBP measurement mode: manual, automatic, STAT, multiple cycle mode.
- NIBP measurement accuracy: average difference of ±5 mmHg.
- Standard deviation: 8 mmHg.
- Automatic measurement intervals: 1-480 min.
SpO2:
- Technique: dual wavelength optical method.
- Measurement range: 0%~100% ±2% for SpO2 range 70~100%.
- PR measurement range: 30~250bpm ±2bpm or ±2%, whichever is greater.
- Low perfusion performance: as low as 0.3%.
EtCO2:
- Technique: infrared optical method.
- Sampling mode: Sidestream.
- Measurement range: 0~150 mmHg.
- Measurement accuracy: 0~40 mmHg ±2 mmHg; 41~70 mmHg ±5%; 71~100 mmHg ±8%; 101~150 mmHg ±10%.
- Flow rate: 50 ml/min ±10 ml/min (sidestream).
Other specifications:
- Power supply: AC 100-240 V, 50/60 Hz, 60 VA.
- Built-in lithium battery: 11.1 V/4400 mAh.
- Display: 15 inch TFT screen.
- Alarm method: 3-level audible-visible alarm.
- Network connection: Ethernet.
- Standard safety: IEC 60601-1.
Standard accessories:
- 12 channel display
- Adult SpO2 probe.
- Adult NIBP cuff.
- SpO2 extension cable.
- 10-lead ECG cable.
- Skin temperature probe.
- Power cable.
- Rechargeable lithium battery.
- Dust protection cover.
- Disposable electrode.
- Manual: GB, FR, IT, ES.
- Single-use PAI monitoring kit.
- PC software: GB, IT, ES.
- EtCO2 configuration.
Regulations and certifications:
- ISO 9001/13485 Certificate.
- CE Certificate.
Features:
- Real-time recording and visualization of the following parameters:
• ECG
• Non-invasive blood pressure (NIBP/PANI)
• Heart rate (PR/RC)
• Oxygen saturation (SpO2)
• Respiration (RESP)
• Temperature (TEMP)
• Exhaled carbon dioxide (EtCO2)
Product characteristics:
- Ergonomic design.
- With intuitive user interface.
- USB port for data transfer and software update.
- 9 waveform traces on the screen.
- Windos style screen view - easy to use.
- Visual and audible alarm for physiological and technical alarms.
- Large capacity storage.
- Suitable for use with original Nellcor sensors.
- Has a protection against defibrillator discharge.
- Equipped with resistance against interference from the electrosurgical apparatus.
- Detection and inhibition of cardiac pacemaker pulse.
- Internal software: GB, DE, FR, PT, ES, IT, PL, TR, RU
- PC software GB, IT, ES.
- Compatible with Windows XP, 7, 8, 10, 11.
Technical specifications:
- ECG input dynamic range: ±(0.5~5 mVp).
- Differential input impedance: =10 MO.
- Bandwidth:
• 0.05~150 Hz (diagnosis)
• 0.5~40 Hz (monitoring)
• 1~20 Hz (operation)
- CMRR: =90 dB ( Diagnosis) / =105 dB (Monitoring and operation).
- Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and automatic sweep speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s.
- HR measurement range: 15~350 bpm ±1% or ±2 bpm, whichever is greater.
- Pacemaker pulse detection and rejection function.
RESP:
- Measurement range: 0~120 rpm ±5% or ±2 rpm, whichever is greater.
TEMP:
- Measurement range: 21.0~50.0 °C ±0.2 °C from 25~45 °C.
NIBP (PANI):
- Technique: oscillometric method.
- Typical measurement time: <30 seconds (adult cuff).
- NIBP measurement range:
• SYS: 40~275 mmHg (adult) / 40~200 mmHg (pediatric) / 40~135 mmHg (neonate).
• DIA: 10~210 mmHg (adult) / 10~150 mmHg (pediatric) / 10~95 mmHg (neonate).
• MAP: 20~230 mmHg (adult) / 20~165 mmHg (pediatric) / 20~110 mmHg (neonate).
- NIBP measurement mode: manual, automatic, STAT, multiple cycle mode.
- NIBP measurement accuracy: average difference of ±5 mmHg.
- Standard deviation: 8 mmHg.
- Automatic measurement intervals: 1-480 min.
SpO2:
- Technique: dual wavelength optical method.
- Measurement range: 0%~100% ±2% for SpO2 range 70~100%.
- PR measurement range: 30~250bpm ±2bpm or ±2%, whichever is greater.
- Low perfusion performance: as low as 0.3%.
EtCO2:
- Technique: infrared optical method.
- Sampling mode: Sidestream.
- Measurement range: 0~150 mmHg.
- Measurement accuracy: 0~40 mmHg ±2 mmHg; 41~70 mmHg ±5%; 71~100 mmHg ±8%; 101~150 mmHg ±10%.
- Flow rate: 50 ml/min ±10 ml/min (sidestream).
Other specifications:
- Power supply: AC 100-240 V, 50/60 Hz, 60 VA.
- Built-in lithium battery: 11.1 V/4400 mAh.
- Display: 15 inch TFT screen.
- Alarm method: 3-level audible-visible alarm.
- Network connection: Ethernet.
- Standard safety: IEC 60601-1.
Standard accessories:
- 12 channel display
- Adult SpO2 probe.
- Adult NIBP cuff.
- SpO2 extension cable.
- 10-lead ECG cable.
- Skin temperature probe.
- Power cable.
- Rechargeable lithium battery.
- Dust protection cover.
- Disposable electrode.
- Manual: GB, FR, IT, ES.
- Single-use PAI monitoring kit.
- PC software: GB, IT, ES.
- EtCO2 configuration.
Regulations and certifications:
- ISO 9001/13485 Certificate.
- CE Certificate.