Reference. 94278UP7000
UP7000 Multiparameter Patient Monitor (ECG, NIBP, PR, TEMP, RESP, SpO2)
Multiparameter patient monitor ECG, RESP, SpO2, TEMP, PR, NIBP.
Personal advice
Description
Multiparameter patient monitor with high-resolution 12.1" TFT color screen with LED backlight, 3-channel ECG amplification, arrhythmia analysis and ST segment analysis.
Features:
- Up to 2,000 groups of parameter data and 24 hours of storage and retrieval of ECG waveforms.
- Displays up to 9 waveforms simultaneously.
- Storage and retrieval of 72-hour ECG waveform data.
- Measurement modes for adults/pediatrics/neonates.
- Visual and audible alarms.
- Built-in rechargeable lithium battery.
- Multilingual internal software: GB, FR, IT, ES, PT, PL, TR, RU, CN.
- 2000 hours data trends with graphical and tabular view.
- Storage of events, ARR and SpO2 of 2000 groups.
Technical specifications:
NIBP Monitoring (PANI)
- Measurement method: oscillometric
- Typical measurement time: <30 seconds.
- Measurement range (systolic pressure): [Adult: 40~275 mmHg] [Pediatric: 40~200 mmHg] [Neonatal: 40~135 mmHg].
- Measurement range (diastolic pressure): [Adult: 10~210 mmHg] [Pediatric: 10~150 mmHg] [Neonatal: 10~95 mmHg].
- Measurement range (mean arterial pressure): [Adult: 20~230 mmHg] [Pediatric: 20~165 mmHg] [Neonatal: 20~110 mmHg].
- Measurement mode: Manual, Auto, STAT.
- Automatic measurement intervals: 1~480min.
TEMP Monitoring:
- Measurement range: 21.0°C ~ 50.0°C.
- Measurement accuracy: ±0.2°C for range from 25.0°C~45.0°C.
SpO2 and PR (RC) Monitoring:
- Transducer: Dual wavelength LED.
- SpO2 measurement range: 0%~100%.
- SpO2 measurement accuracy: 2% for a range of 70% to 100%.
- Low perfusion performance: As low as 0.4%.
- PR measurement range: 0bpm~250bpm.
- PR measurement accuracy: ±2bpm or ±2%, whichever is greater.
ECG Monitoring:
- Input dynamic range: ±0.5 mVp ~ ±5 mVp.
- HR measurement range: 15 bpm ~ 350 bpm.
- HR measurement accuracy: ±1% or ±2bpm, whichever is greater.
- HR alarm delay time: ≤10s.
- Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto
- Sweep speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
- ECG noise level: ≤30μVp-p
- ECG input loop current: ≤0.1 μA
- Differential input impedance: ≥10Mohm
- Common mode rejection ratio: ≥105dB (monitoring mode) (CMRR): ≥89dB (diagnostic mode).
- Time constant ≥0.3 s (monitoring mode), ≥3.2 s (diagnostic mode).
RESP Monitoring
- Measurement method: thoracic impedance.
- Monitoring range: 0 rpm ~ 120 rpm.
- Measurement accuracy: ±5% or ± rpm, whichever is greater.
Other technical specifications:
- Power supply: 100 ~ 240 Vac, 50/60 Hz.
- Built-in 4400 mAh lithium battery.
- 12.1 inch screen (Resolution 800*600).
- Alarm mode: Audible-visual alarm.
- Network port: Ethernet port.
Includes:
- Adult SpO2 probe.
- Adult PANI cuff.
- Skin temperature probe.
- 5 lead ECG cable (RA - LA - LL - PL - C).
- Rechargeable battery.
- Power cable.
- Disposable electrode.
Features:
- Up to 2,000 groups of parameter data and 24 hours of storage and retrieval of ECG waveforms.
- Displays up to 9 waveforms simultaneously.
- Storage and retrieval of 72-hour ECG waveform data.
- Measurement modes for adults/pediatrics/neonates.
- Visual and audible alarms.
- Built-in rechargeable lithium battery.
- Multilingual internal software: GB, FR, IT, ES, PT, PL, TR, RU, CN.
- 2000 hours data trends with graphical and tabular view.
- Storage of events, ARR and SpO2 of 2000 groups.
Technical specifications:
NIBP Monitoring (PANI)
- Measurement method: oscillometric
- Typical measurement time: <30 seconds.
- Measurement range (systolic pressure): [Adult: 40~275 mmHg] [Pediatric: 40~200 mmHg] [Neonatal: 40~135 mmHg].
- Measurement range (diastolic pressure): [Adult: 10~210 mmHg] [Pediatric: 10~150 mmHg] [Neonatal: 10~95 mmHg].
- Measurement range (mean arterial pressure): [Adult: 20~230 mmHg] [Pediatric: 20~165 mmHg] [Neonatal: 20~110 mmHg].
- Measurement mode: Manual, Auto, STAT.
- Automatic measurement intervals: 1~480min.
TEMP Monitoring:
- Measurement range: 21.0°C ~ 50.0°C.
- Measurement accuracy: ±0.2°C for range from 25.0°C~45.0°C.
SpO2 and PR (RC) Monitoring:
- Transducer: Dual wavelength LED.
- SpO2 measurement range: 0%~100%.
- SpO2 measurement accuracy: 2% for a range of 70% to 100%.
- Low perfusion performance: As low as 0.4%.
- PR measurement range: 0bpm~250bpm.
- PR measurement accuracy: ±2bpm or ±2%, whichever is greater.
ECG Monitoring:
- Input dynamic range: ±0.5 mVp ~ ±5 mVp.
- HR measurement range: 15 bpm ~ 350 bpm.
- HR measurement accuracy: ±1% or ±2bpm, whichever is greater.
- HR alarm delay time: ≤10s.
- Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto
- Sweep speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
- ECG noise level: ≤30μVp-p
- ECG input loop current: ≤0.1 μA
- Differential input impedance: ≥10Mohm
- Common mode rejection ratio: ≥105dB (monitoring mode) (CMRR): ≥89dB (diagnostic mode).
- Time constant ≥0.3 s (monitoring mode), ≥3.2 s (diagnostic mode).
RESP Monitoring
- Measurement method: thoracic impedance.
- Monitoring range: 0 rpm ~ 120 rpm.
- Measurement accuracy: ±5% or ± rpm, whichever is greater.
Other technical specifications:
- Power supply: 100 ~ 240 Vac, 50/60 Hz.
- Built-in 4400 mAh lithium battery.
- 12.1 inch screen (Resolution 800*600).
- Alarm mode: Audible-visual alarm.
- Network port: Ethernet port.
Includes:
- Adult SpO2 probe.
- Adult PANI cuff.
- Skin temperature probe.
- 5 lead ECG cable (RA - LA - LL - PL - C).
- Rechargeable battery.
- Power cable.