PC-900 Multiparameter Monitor (NIBP, PR, TEMP, SpO2)
Multiparameter Monitor PC-900 (NIBP, PR, TEMP, SpO2)
Description
Vital signs monitor for continuous monitoring of Non-Invasive Blood Pressure (NIBP), Pulse Rate (PR), and Oximetry (SpO2).
Temperature can be chosen between skin, rectal, or infrared ear (the chosen sensor must be ordered separately).
Characteristics:
•7" touchscreen with wave graphic and numerical values of SpO2/ECG
•Tall design for comfortable and pleasant use
•Memory for up to 12000 NIBP groups, 3000 SpO2 groups, and alarms
•Historical data can be reviewed as waves, list, or trend charts
•Data export and software update by USB
•Available SpO2 compatible with Nellcor, Pani SunTech, and Tympanic Thermometer
•Power supply 100-240 Vac, 50/60 Hz
•Internal Lithium-Ion battery 11.1V/4400 mAh
NIBP (PANI)
-Method: Oscillometric
-Measurement accuracy:
Max. average deviation: ±5 mmHg
Max. average deviation: 8 mmHg
-Systolic pressure:
Adult: 40 mmHg-275 mmHg
Pediatric: 40 mmHg-200 mmHg
Neonate: 40 mmHg-135 mmHg
-Diastolic pressure:
Adult: 10 mmHg-210 mmHg
Pediatric: 10 mmHg-150 mmHg
Neonate: 10 mmHg-95 mmHg
-Mean Arterial Pressure:
Adult: 20 mmHg-230 mmHg
Pediatric: 20 mmHg-165 mmHg
Neonate: 20 mmHg-110 mmHg
-Measurement modes: Manual, Auto, STAT
-Overpressure protection limit:
Adult: 300 mmHg
Pediatric: 240 mmHg
Neonate: 150 mmHg
SpO2
-Transducer: Led dual wavelength
-SpO2 Measurement range: 35%-100%
-SpO2 Measurement accuracy Low perfusion level: 3% between 70% to 100% Less than 0.4%
PR (HR)
-Measurement range: 30lpm – 240lpm
-Measurement accuracy: ±2%
TEMP
-Measurement range: 21.0 °C – 50.0 °C
-Measurement accuracy: + 0.2 °C in the range of 25 °C – 45 °C
Temperature can be chosen between skin, rectal, or infrared ear (the chosen sensor must be ordered separately).
Characteristics:
•7" touchscreen with wave graphic and numerical values of SpO2/ECG
•Tall design for comfortable and pleasant use
•Memory for up to 12000 NIBP groups, 3000 SpO2 groups, and alarms
•Historical data can be reviewed as waves, list, or trend charts
•Data export and software update by USB
•Available SpO2 compatible with Nellcor, Pani SunTech, and Tympanic Thermometer
•Power supply 100-240 Vac, 50/60 Hz
•Internal Lithium-Ion battery 11.1V/4400 mAh
NIBP (PANI)
-Method: Oscillometric
-Measurement accuracy:
Max. average deviation: ±5 mmHg
Max. average deviation: 8 mmHg
-Systolic pressure:
Adult: 40 mmHg-275 mmHg
Pediatric: 40 mmHg-200 mmHg
Neonate: 40 mmHg-135 mmHg
-Diastolic pressure:
Adult: 10 mmHg-210 mmHg
Pediatric: 10 mmHg-150 mmHg
Neonate: 10 mmHg-95 mmHg
-Mean Arterial Pressure:
Adult: 20 mmHg-230 mmHg
Pediatric: 20 mmHg-165 mmHg
Neonate: 20 mmHg-110 mmHg
-Measurement modes: Manual, Auto, STAT
-Overpressure protection limit:
Adult: 300 mmHg
Pediatric: 240 mmHg
Neonate: 150 mmHg
SpO2
-Transducer: Led dual wavelength
-SpO2 Measurement range: 35%-100%
-SpO2 Measurement accuracy Low perfusion level: 3% between 70% to 100% Less than 0.4%
PR (HR)
-Measurement range: 30lpm – 240lpm
-Measurement accuracy: ±2%
TEMP
-Measurement range: 21.0 °C – 50.0 °C
-Measurement accuracy: + 0.2 °C in the range of 25 °C – 45 °C