Reference. 94278PC00060018-1

Portable vital signs monitor PC 300 Spot-Check with glucometer (NIBP, PR, TEMP and SpO2)

Portable vital signs monitor capable of displaying readings on temporal temperature, blood pressure, heart rate, blood oxygen saturation, and blood sugar level.
Personalized attention
Personal advice
-10% 458,00€ 509,00€ (554,18€ VAT INCLUDED)
Buy
Secure payment
Product in stock. Estimated delivery 48-72 hours.

Description

This vital signs monitor has a compact and lightweight design intended for easy transportation and use in all types of environments, both professional and domestic. It includes a numeric display capable of showing readings about the user's temperature, heart rate, blood pressure, blood oxygen saturation level, and blood sugar level. Moreover, all its measurement systems have been carefully calibrated and are FDA certified, so their readings are completely reliable and true to reality.

General features
- Ability to record up to 6,000 NIBP data readings
- Storage of 100 different patients, with a maximum capacity of 999 records per user
- Fast ear probe TEMP measurement result in 5 seconds
- Equipped with Bluetooth technology and USB port
- The collected data can be transferred and viewed in real time on other smart devices, both Android and iOS and Windows
- Data manageable through specialized computer software (not included and at additional cost)
- Built-in rechargeable lithium battery
- Communication protocols available on demand
- Classified as a Class IIa medical device
- Manufactured according to FDA specifications

Technical specifications

General specifications
- Dimensions: 165 x 96 x 68 mm
- Screen size: 4.3"
- Battery: built-in 3.7 V lithium ion battery
- Operating voltage: 3.6 - 4.2 VDC
- Operating current: 800 mA
- Charger: 100 - 240 VAC, 50/60 Hz, 5 VDC or USB

NIPB module specifications (PANI)
- Measurement method: oscillometric
- Measurement range: 0 mmHg - 300 mmHg (adult/pediatric)
- Systole: 60 mmHg - 240 mmHg
- Diastole: 30 mmHg - 180 mmHg
- Maximum standard deviation: ≤ 8 mmHg (1.067 kPa)
- Cuff inflation time: < 20 seconds (standard adult version)
- Overpressure protection limit: ≤ 300 mmHg (39.9 kPa)

PR module specifications (RC)
- Measurement range: 30 bpm - 240 bpm
- Accuracy: ± 2 bpm or ± 2%

TEMP module specifications
- Measurement range: 32 - 43℃
- Accuracy: ± 0.2℃ (between 36 and 39℃), ± 0.3℃ (other values)
- Response time: < 5 s
- Probe: infrared ear probe


SpO2 module specifications
- Measurement technique: optical, with double wavelength
- Measurement range: 0% - 100%
- Accuracy: ± 3% (range of 70% - 100%)
- Value update time: every second

Glucose meter specifications
- Analysis sample: peripheral blood
- Blood sample volume: 0.6 μL
- Detection range: 1.1 ~ 3.3 mmol/L
- Analysis time: 8 seconds

Standard accessories
- Adult SpO2 probe
- Blood glucose meter
- Adult NIBP cuff
- Ear thermometer (probe covers not included)
- Lithium battery with charger
- Transport bag
- User manual: GB, FR, IT, ES

Optional accessories (not included)
- Transport case
- Pediatric Sp02 Probe (Ref. 400135164)
- Pediatric NIBP cuff 10-19 cm (Ref. 400135166)
- Adult NIBP cuff 22-30 cm (Ref. 400135167)
- Adult NIBP cuff 27-42 cm (Ref. 400135168)
- Adult NIBP cuff 40-48 cm (Ref. 400135169)
- ECG Mode