PC 3000 Multiparameter Monitor (ECG, NIBP, PR, TEMP, RESP, SpO2)

Multiparameter Monitor PC 3000 (ECG, NIBP, PR, TEMP, RESP, SpO2)
-46% 585,00€ 1.088,00€ (707,85€ VAT INCLUDED)
Buy
Secure payment
Product in stock. Estimated delivery 48-72 hours.

Description

Creative medical

Multi-parameter Monitor PC 3000

Features:

• Screen of (800x480) 7'' high-resolution TFT color, with 5-channel waveform
• Standard parameters: ECG, RESP, Sp02, NIBP, 2-TEMP, arrhythmias and ST segment analysis
• Up to 800 groups of parameter data and 24 hours of ECG waveform storage
• 480 hours of graph and tubular trends for all parameters
• Display of 7 simultaneous ECG channels
• Protection against interference from defibrillator, electrosurgery scalpel
• Modes of measurement Adult / Pediatric
• Audible and visual alarms; network connectivity

Technical specifications: 
NIBP (NIBP) monitoring

• Measurement method: Automatic measurement by the oscillatory method
• Cuff inflation time: <10 seconds (standard adult cuff)
• Initial cuff inflation pressure: adult mode: <180mmHg; child mode: <120mmHg
• Overpressure protection limit: adult mode: 300mmHg; child mode: 240mmHg

Measurement range
• Systolic pressure: Pediatric: 40-200 mmHg; Adult: 40-225 mmHg
Diastolic pressure : Pediatric: 20-165 mmHg; Adults: 20 to 215 mmHg
• Mean arterial pressure: Pediatric: 10-150 mmHg; Adults: 10-195 mmHg 
• Measurement accuracy: ± 10% systolic ± 10% diastolic ± 10% MAP
• Measurement mode: manual, automatic, STAT
• Automatic measurement: 1 ~ 240 min
• Intervals: interval tolerance: <10s

TEMP monitoring
• Measurement range, accuracy: 25.0 ° C ~ 45.0 ° C, ± 0.2 ° C

SpO2 and PR (HR)
• Transducer: dual wavelength LED
• SpO2 measurement range: 35% ~ 100%
• Low perfusion ability: 0.4% ~ 5%
• SpO2 accuracy: 70% ~ 100% ± 3%
• PR measurement range: 30bpm ~ 250bpm
• PR measurement accuracy: ± 2bpm

ECG monitoring
• Heart rhythm measurement: ± 0.4mVp ~ ± 5mVp
• Heart rate display range: 20bpm ~ 250bpm
• Reading accuracy*: ± 1% or ± 2 ppm, whichever is greater
• Heart Rate Alarm Delay: = 10s
• Sensitivity Selection: Auto, × 1/2, × 1, × 2, 4 × tolerance: = 5%
• Sweep speed: 12.5 mm/s, 25 mm/s, 50 mm/s tolerance: = 10%
• ECG noise level: = 30μVP-P
• ECG input loop current: = 0.1μA
• Input impedance: = 5MO
• Common mode rejection ratio: = 89dB
• Time constant: Monitoring mode = 0.3s
• Diagnostic mode = 3.2s
• Frequency Response: Tracking mode: 0.5 Hz ~ 25 Hz
• Diagnostic mode: 0.05 Hz ~ 75 Hz

RESP monitoring
• Monitoring range, accuracy: 0 rpm ~ 120 rpm, ± 5% or 2rpm, whichever is greater
• RESP alarm range: 0bpm ~ 100bpm
• Alarm tolerance: ± 10%

Other Technical Specifications
• Power supply: 100 ~ 250 Vac, 50 / 60Hz
• Power consumption: <80 VA
• Battery duration: 120 minutes
• Display mode: 7 inch TFT LCD color
• Alarm mode: Audio-visual alarm
• Network port: LCD serial port / Net

Standard accessories
1 ECG Cable
1 SpO2 Probe
1 AC Power Adapter 
1 Li-ion battery 
1 NIBP Cuff
Body temperature transducer
Power cord
10 disposable electrodes
User manual