Reference. 400133800

Riester RVS-100 multiparametric monitor (NIBP, PR, SpO2)

Riester RVS-100 multiparameter monitor (NIBP, PR, SpO2)
Riester RVS-100 multiparametric monitor (NIBP, PR, SpO2)
Riester RVS-100 multiparametric monitor (NIBP, PR, SpO2)
Riester RVS-100 multiparametric monitor (NIBP, PR, SpO2)
Riester RVS-100 multiparametric monitor (NIBP, PR, SpO2)
Riester RVS-100 multiparametric monitor (NIBP, PR, SpO2)
Riester RVS-100 multiparametric monitor (NIBP, PR, SpO2)
3.150,00€ (3.811,50€ VAT INCLUDED)
Buy
Secure payment
Approximate delivery time of 10 to 20 days

Description

Riester
Riester RVS-100 multiparameter monitor that allows precise and rigorous monitoring of the following parameters: non-invasive blood pressure (NIBP), oxygen saturation (SpO2) and pulse rate.

Optionally and at an additional cost, it is possible to purchase the model with a printer.

Features:
- Allows monitoring of parameters in both adult and pediatric and neonatal patients.
- User-friendly and very easy to use interface.
- Low battery and battery charge indicator.

- 3 measurement modes: monitor, Spot-check and Triage.
- 8” TFT color touchscreen with self-explanatory user interface and integrated help function.
- Displays SYS, DIA, MAP, Pulse, Temp and Plethysmogram.
- Programmable with EWS: NEWS, MEWS and 5 customizable profiles.
- Clinical grade NIBP, including average mode (2-5 readings) and neonate mode.
- Bluetooth connectivity for connection to Riester 'tymPRO' and 'sensioPRO' thermometers.
- Riester Oximax SpO2 including neonate mode.
- Connectivity with the EMR using the HL7 standard.
- Standard LAN connectivity.
- Programmable audible and visual alarms with 3 priority levels.
- Supports calling the medical professional through the RJ11 port.
- Internal memory with capacity for 5,000 measurements.
- Lithium-ion battery with 11 hours of operation (automatic mode, 15-min intervals).

Certificates:
- CE Class II B medical product.
- Alarm tones comply with the requirements of the IEC 60601-1-8 standard.
- In accordance with ISO 9001 and ISO 13485 standards.

Technical specifications:
- Monitors the following parameters:
• NIBP (PANI):
    - Measurement method: automatic oscillometric.
    - Measurement range:
    • Adult: SYS 30-270 mmHg, DIA 10-220 mmHg, MAP 20-235 mmHg.
    • Pediatric: SYS 30-235 mmHg, DIA 10-220 mmHg, MAP 20-225 mmHg.
    • Neonate: SYS 30-135 mmHg, DIA 10-110 mmHg, MAP 20-125 mmHg.
    - Cuff pressure range: 0-280 mmHg, 1 mmHg resolution.
    - Pressure accuracy:
    • Static: ±3 mmHg.
    • Clinical: ±5 mmHg, standard deviation =8 mmHg.
    - Pulse frequency range: 40-240 bpm, 1 bpm accuracy.
    - Initial inflation pressure: adult 160 mmHg, pediatric 130 mmHg, neonate 75 mmHg.
    - Double overpressure protection (hardware and software): adult 297 ±3 mmHg, pediatric 252 ±3 mmHg, neonate 147 ±3 mmHg.
    - Alarm range: SYS, DIA, MAP 0-300 mmHg.
• SpO2:
    - Measurement range: 0-100%, 1% resolution.
    - Accuracy:
    • ±2% (70-100%).
    • ±3% (40-69%).
    • Not specified (0-39%).
    - Alarm range: 0-100%.
    - Average time: 4, 8, 16 seconds.
• PR (HR):
    - Measurement range: 20-250 bpm, 1 bpm resolution.
    - Accuracy: ±1% or ±1 bpm, whichever is greater.
• Ports:
    - 1 AC power input.
    - 1 standard RJ45 interface.100 BASE-TX, IEEE 802.3.
    - 4 USB ports.
    - 1 equipotential grounding point.
    - 1 RJ11 connector.
    - DC output port 15 V/1.2 A.
- Noise level: 45-85 dB at 1 m.
- Power supply: 100-240 V AC, 50/60 Hz.
- 10.8 V DC 6600 mAh rechargeable lithium-ion battery.
- 100% charge time: 6 hours.
- Operating time: approximately 11 hours with new and fully charged battery with SpO2, temperature and NIBP connected in AUTO mode (15-minute interval).
- Dimensions: 303x110x230 mm.
- Weight: 3.6 kg.

Includes: 
- Adult SpO2 sensor.
- SpO2 extension cable.
- NIBP extension tube.
- 2 adult and large adult size cuffs with connectors.
- User manual in the following languages: GB and IT (FR, DE, ES and RU on request).

Alternative products