Reference. 1208TOO06

Adult defibrillation electrodes for Medtronic, Mindray, Lecor and Bexen equipment. 1 pair

Electrodes for adult patients indicated for synchronized cardioversion processes, monitoring with electrocardiogram and defibrillation.
Adult defibrillation electrodes for Medtronic, Mindray, Lecor and Bexen equipment. 1 pair
Adult defibrillation electrodes for Medtronic, Mindray, Lecor and Bexen equipment. 1 pair
Adult defibrillation electrodes for Medtronic, Mindray, Lecor and Bexen equipment. 1 pair
Adult defibrillation electrodes for Medtronic, Mindray, Lecor and Bexen equipment. 1 pair
17,10€ (20,69€ VAT INCLUDED)
Buy
Secure payment
Product in stock. Estimated delivery 48-72 hours.

Description

Non-sterile disposable electrodes designed for defibrillation processes, EKG monitoring, and synchronized cardioversion in adult patients. Completely biocompatible, easy to place and use, and capable of withstanding up to 15 sequential 360 J defibrillation discharges.

General Features
- Electrodes suitable for defibrillation, synchronized cardioversion, and EKG monitoring
- Capable of withstanding up to 15 sequential 360 J defibrillation discharges
- Free of natural latex, phthalates, and biologically derived compounds
- Non-cytotoxic, non-sensitizing, and non-irritating

Technical Specifications
- Electrode dimensions: 105 x 155 mm
- Active area dimensions: 79.45 cm2
- Recommended usage time: 24 h
- Minimum patient weight: 10 kg
- Shelf life: 2 years from the date of manufacture
- Compatibility: Physio-Control/Medtronic equipment (Lifepack 12, Lifepack 20e, and Lifepack 1000), Mindray (Beneheart D3), Lecor (Cor-Res A6S), and Bexen (Reanibex 200)

Materials
- Support: 1 millimeter thick white polyethylene foam with a waterproof cell and biocompatible acrylic adhesive
- Conductive area: tin foil with biocompatible acrylic-based hydrogel
- Protector: polyethylene terephthalate
- Connection cable: copper (65/0.127 mm) covered with non-toxic PVC
- Connector mold: plastic material
- Ring terminals: brass
- Washer: ethylene-vinyl acetate/thermoplastic elastomer

Electrical Properties
- Low frequency AC impedance at 10 Hz: < 3000 Ω
- Low frequency AC impedance at 30 kHz: < 10 Ω
- High frequency AC impedance: < 5 Ω
- Defibrillation overload recovery after 4 s: < 500 mV
- Defibrillation overload recovery after 60 s: < 400 mV
- DC Offset Voltage: < 100 mV

Standards and Certifications
- IEC 60601-2-4
- ISO 10993-5
- ISO 10993-10
- ISO 13485
- RoHS Regulations
- Directive 93/42/EEC, Class I medical product