Reference. 94278NEOS120
NEO ECG S120 ECG Tablet
ECG Tablet for the acquisition and visualization of 9/12 lead waveforms, as well as heart rate detection
Personal advice
Description
Portable and lightweight ECG tablet for use in medical institutions to acquire resting ECG signals from adult and pediatric patients through the body surface with ECG electrodes and analyze the data for clinical diagnosis. It records and displays 9/12 lead waveforms and detects heart rate. It features a 7" high-resolution color touchscreen, which is especially easy to operate
It allows storing, previewing, reviewing, editing, and uploading patient data through wireless transmission of ECG data via WiFi and mobile networks. In addition, patient data can be exported via a USB connector.
Features:
- Glasgow algorithm.
- 4 sampling modes: pre-sampling, real-time sampling, periodic sampling, and activation sampling.
- Automatic detection and marking of stimulation.
-Automatic analysis of RR, VFC, drug test, ECG event mode.
- Files in multiple formats: Carewell ECG, PDF, BMP, HL7, DICOM, SCP.
- Freezing of the ECG waveform on the screen.
- Virtual keyboard and barcode scanning to insert patient information.
- External DC power supply and built-in rechargeable battery.
- Software in various languages: GB, FR, IT, ES, PT, DE, GR, PL.
Technical specifications:
- ECG leads: 9, 12 synchronous acquisition.
- A/D resolution: 24 bits.
- Heart rate range: 30 bpm-300 bpm ± 1 Input circuit current: = 10 nA.
- Sensitivity: automatic, 2.5, 5, 10, 20, 40 mm/mV, less than ± 5% error.
- Printing speed: 5, 6.25, 10, 12.5, 25, 50 mm/s, less than ± 3% error.
- Sampling rate: 32000 samples/s.
- Filters: AC (50-60 Hz, off), EMG (25-35-45 Hz off), ADS (0.01-0.05-0.32-0.67 Hz), Low pass filter (75-100-150-300 Hz off).
- Frequency response: 0.01-350 Hz (+ 0.4-3.0 db).
- Minimum selectable signal: 20 μVp-p.
- Electrical:
• Internal noise: = 12.5 μV.
• Input impedance: = 100 MO (10 Hz).
• Calibration voltage: 1 mV ± 2%.
• Depolarization voltage: ± 900 mV, ± 5%.
• Common mode rejection: = 140 dB (AC Filter activated).
• Odorless mode rejection: = 120 dB (AC filter deactivated).
- Amplitude quantification: 0.95 μV/LSB.
- Recovery time after discharge: < 10 s.
- Display: 7" color touchscreen.
- Size: 19.7 x 11.2 x h 2.6 cm.
- Weight: 0.8 kg.
Standard accessory:
- 1 ECG cable (IEC, Ø 4 mm, banana connector).
- 6 precordial suction electrodes for adults (Ø 4 mm).
- 4 adult limb clamp electrodes.
- 1 rechargeable lithium battery.
- 1 power adapter.
- Multilingual manual: GB, IT, on request FR, ES, PT, DE, GR, PL.
It allows storing, previewing, reviewing, editing, and uploading patient data through wireless transmission of ECG data via WiFi and mobile networks. In addition, patient data can be exported via a USB connector.
Features:
- Glasgow algorithm.
- 4 sampling modes: pre-sampling, real-time sampling, periodic sampling, and activation sampling.
- Automatic detection and marking of stimulation.
-Automatic analysis of RR, VFC, drug test, ECG event mode.
- Files in multiple formats: Carewell ECG, PDF, BMP, HL7, DICOM, SCP.
- Freezing of the ECG waveform on the screen.
- Virtual keyboard and barcode scanning to insert patient information.
- External DC power supply and built-in rechargeable battery.
- Software in various languages: GB, FR, IT, ES, PT, DE, GR, PL.
Technical specifications:
- ECG leads: 9, 12 synchronous acquisition.
- A/D resolution: 24 bits.
- Heart rate range: 30 bpm-300 bpm ± 1 Input circuit current: = 10 nA.
- Sensitivity: automatic, 2.5, 5, 10, 20, 40 mm/mV, less than ± 5% error.
- Printing speed: 5, 6.25, 10, 12.5, 25, 50 mm/s, less than ± 3% error.
- Sampling rate: 32000 samples/s.
- Filters: AC (50-60 Hz, off), EMG (25-35-45 Hz off), ADS (0.01-0.05-0.32-0.67 Hz), Low pass filter (75-100-150-300 Hz off).
- Frequency response: 0.01-350 Hz (+ 0.4-3.0 db).
- Minimum selectable signal: 20 μVp-p.
- Electrical:
• Internal noise: = 12.5 μV.
• Input impedance: = 100 MO (10 Hz).
• Calibration voltage: 1 mV ± 2%.
• Depolarization voltage: ± 900 mV, ± 5%.
• Common mode rejection: = 140 dB (AC Filter activated).
• Odorless mode rejection: = 120 dB (AC filter deactivated).
- Amplitude quantification: 0.95 μV/LSB.
- Recovery time after discharge: < 10 s.
- Display: 7" color touchscreen.
- Size: 19.7 x 11.2 x h 2.6 cm.
- Weight: 0.8 kg.
Standard accessory:
- 1 ECG cable (IEC, Ø 4 mm, banana connector).
- 6 precordial suction electrodes for adults (Ø 4 mm).
- 4 adult limb clamp electrodes.
- 1 rechargeable lithium battery.
- 1 power adapter.