Reference. 400130693
MB 200 Touch Diathermy Electrosurgical Unit mono-bipolar 200 Watt
200W high-frequency electrosurgical unit, suitable for mono, bipolar, and precision microsurgery, without tissue alterations.
Personal advice
Description
The Diatermo MB 200 Touch electrosurgical unit is a high-frequency 200W electro-surgical equipment, suitable for mono, bipolar and precision microsurgery, without tissue alterations.
This equipment allows pure CUT, BLEND coagulation-cutting, improved incision with reduced eschar production, superficial FORCED COAG coagulation, deep coagulation in the absence of necrosis SOFT COAG, bipolar CUT, COAG and SEALING, FULGURATION.
It allows obtaining a high-frequency operating power even in very short times (fractions of a second).
The digital reading of the emitted power and control over the operational functions through microcontrol ensure the perfect reliability of the working conditions.
Due to its ergonomic and safety features, the Diatermo MB 200 Touch allows for professional-style surgery.
If a bipartite neutral plate is used, the device checks the contact between the electrode and the patient to ensure that the neutral plate is properly connected.
In addition, the ability to modify functions and activate power emission from the handle allows surgeries to be performed without diverting attention from the operated area.
It has software developed to provide a simple, functional and intuitive work experience. With just the touch of a finger, you can customize the screen, work settings, change cutting or coagulation power, and manage all device functions.
Technical specifications:
- Maximum power:
• PURE CUT: 200 W - 300 Ohm.
• BLEND: 150 W - 300 Ohm.
• IMPROVED: 150 W - 300 Ohm.
• FORCED COAG: 150 W - 200 Ohm.
• SOFT COAG: 100 W - 200 Ohm.
• FULGURATION: 100 W - 1000 Ohm.
• BIPOLAR SEALING : 200 W - 50 Ohm.
• BIPOLAR COAG: 120 W - 50 Ohm.
• BIPOLAR CUT: 120 W - 50 Ohm.
- Frequency pulse emission time: 10 ms - 30 sec.
- Frequency pulse interval: 1 - 30.
- Patient circuit: F
- Selectable input voltage: 100 - 240 VAC:
- Maximum absorption power: 750 VA.
- Working frequency: 360 KHz.
- Size: 370 x 145 x 300 mm.
- Weight: 6 kg.
- Controls: Patient circuit/plate monitoring, Output power monitoring, Self-diagnosis.
- Safety: EN60601-1; EN60601-1-2; EN60601-2-2.
- Electrical classification: I CF MDD 93/42 / EC: II b.
Standard accessories:
- Flexible steel neutral plate with cable.
- Kit 10 standard short electrodes Ø 2.4 mm.
- 5 m power cable.
- Handle and electrode holder.
- Reusable handle with switches.
- Waterproof pedal.
This equipment allows pure CUT, BLEND coagulation-cutting, improved incision with reduced eschar production, superficial FORCED COAG coagulation, deep coagulation in the absence of necrosis SOFT COAG, bipolar CUT, COAG and SEALING, FULGURATION.
It allows obtaining a high-frequency operating power even in very short times (fractions of a second).
The digital reading of the emitted power and control over the operational functions through microcontrol ensure the perfect reliability of the working conditions.
Due to its ergonomic and safety features, the Diatermo MB 200 Touch allows for professional-style surgery.
If a bipartite neutral plate is used, the device checks the contact between the electrode and the patient to ensure that the neutral plate is properly connected.
In addition, the ability to modify functions and activate power emission from the handle allows surgeries to be performed without diverting attention from the operated area.
It has software developed to provide a simple, functional and intuitive work experience. With just the touch of a finger, you can customize the screen, work settings, change cutting or coagulation power, and manage all device functions.
Technical specifications:
- Maximum power:
• PURE CUT: 200 W - 300 Ohm.
• BLEND: 150 W - 300 Ohm.
• IMPROVED: 150 W - 300 Ohm.
• FORCED COAG: 150 W - 200 Ohm.
• SOFT COAG: 100 W - 200 Ohm.
• FULGURATION: 100 W - 1000 Ohm.
• BIPOLAR SEALING : 200 W - 50 Ohm.
• BIPOLAR COAG: 120 W - 50 Ohm.
• BIPOLAR CUT: 120 W - 50 Ohm.
- Frequency pulse emission time: 10 ms - 30 sec.
- Frequency pulse interval: 1 - 30.
- Patient circuit: F
- Selectable input voltage: 100 - 240 VAC:
- Maximum absorption power: 750 VA.
- Working frequency: 360 KHz.
- Size: 370 x 145 x 300 mm.
- Weight: 6 kg.
- Controls: Patient circuit/plate monitoring, Output power monitoring, Self-diagnosis.
- Safety: EN60601-1; EN60601-1-2; EN60601-2-2.
- Electrical classification: I CF MDD 93/42 / EC: II b.
Standard accessories:
- Flexible steel neutral plate with cable.
- Kit 10 standard short electrodes Ø 2.4 mm.
- 5 m power cable.
- Handle and electrode holder.
- Reusable handle with switches.
- Waterproof pedal.