Reference. 10444002519
Steam Autoclave Autester ST DRY PV-III 80 liters vertical
Vertical Autester ST DRY PV-III 80 liters steam autoclave
Personal advice
Description
Steam Autoclave Autester ST DRY PV-III 80 liters vertical.
It has microprocessor process control, automatic drying and purging system by fractional vacuum.
Allows temperature regulation from 105 °C to 134 °C (0.21 A 2 bar).
Features:
• Exterior furniture and countertop in stainless steel.
• Tank and lid in stainless steel.
• Purging by fractional and atmospheric vacuum pump.
• External steam generator.
• Water tank to feed the boiler.
• Possibility of feeding the boiler from an external water intake.
• 6 operating modes.
• Output for printer (optional)
• USB output for data registration in PEN-DRIVE and connection to the computer.
• Connection for a second control probe (optional).
• Storage for 9 programs fully configurable by the user.
Safety:
• Device that prevents the lid from opening while the chamber is under pressure.
• Safety valve. Prevents pressure from exceeding the maximum limit.
• Safety pressure switch. Disconnects the heating in case of overpressure.
• Thermal protection casing of the lid.
• Door detector properly closed.
Microprocessor functions:
The microprocessor controls the execution of the air extraction, sterilization and drying process, executing the procedures and orders selected by the operator, regulating the following parameters:
• Sterilization temperature from 105 °C to 134 °C.
• Sterilization time from 3' to 59'.
• Drying time from 20' to 60'.
• Up to 10 programs configurable by the user.
• Six operating modes:
- Solids 1
- Solids 2 fractions.
- Solids 3 fractions.
- Drying.
- Liquids.
- Liquids 2 probes.
• Verification test
- Vacuum.
- Bowie Dick.
• Configuration
- Units.
- Languages (Spanish, English, French).
- USB module or printer.
- Clock: date/time.
- External water intake: on/off.
• Password
• Calibration
- Probe 1 temperature
- Probe 2 temperature
- Water dosing.
• Audible and visual alarm for over temperature and insufficient temperature.
• Detection and memorization of network failures
• Safety thermostat (TS) by software
• Data logging of sterilization cycles with capacity for more than 500 cycles.
• Internal cleaning program
• PC software
• Temperature correction
• Summary user manual on screen
• Graphical representation of the process in real time
Any operating or execution error is translated into a message on the control panel and an audible warning automatically disconnecting the steam generator.
Standards:
• EN 61010-1 Safety requirements for laboratory equipment.
• EN 61010-2-040 Safety requirements for laboratory equipment. Sterilizers.
• EN 61326 Electromagnetic compatibility requirements for laboratory equipment.
*Supplied without basket and without drums.
Installation not included.
It has microprocessor process control, automatic drying and purging system by fractional vacuum.
Allows temperature regulation from 105 °C to 134 °C (0.21 A 2 bar).
Features:
• Exterior furniture and countertop in stainless steel.
• Tank and lid in stainless steel.
• Purging by fractional and atmospheric vacuum pump.
• External steam generator.
• Water tank to feed the boiler.
• Possibility of feeding the boiler from an external water intake.
• 6 operating modes.
• Output for printer (optional)
• USB output for data registration in PEN-DRIVE and connection to the computer.
• Connection for a second control probe (optional).
• Storage for 9 programs fully configurable by the user.
Safety:
• Device that prevents the lid from opening while the chamber is under pressure.
• Safety valve. Prevents pressure from exceeding the maximum limit.
• Safety pressure switch. Disconnects the heating in case of overpressure.
• Thermal protection casing of the lid.
• Door detector properly closed.
Microprocessor functions:
The microprocessor controls the execution of the air extraction, sterilization and drying process, executing the procedures and orders selected by the operator, regulating the following parameters:
• Sterilization temperature from 105 °C to 134 °C.
• Sterilization time from 3' to 59'.
• Drying time from 20' to 60'.
• Up to 10 programs configurable by the user.
• Six operating modes:
- Solids 1
- Solids 2 fractions.
- Solids 3 fractions.
- Drying.
- Liquids.
- Liquids 2 probes.
• Verification test
- Vacuum.
- Bowie Dick.
• Configuration
- Units.
- Languages (Spanish, English, French).
- USB module or printer.
- Clock: date/time.
- External water intake: on/off.
• Password
• Calibration
- Probe 1 temperature
- Probe 2 temperature
- Water dosing.
• Audible and visual alarm for over temperature and insufficient temperature.
• Detection and memorization of network failures
• Safety thermostat (TS) by software
• Data logging of sterilization cycles with capacity for more than 500 cycles.
• Internal cleaning program
• PC software
• Temperature correction
• Summary user manual on screen
• Graphical representation of the process in real time
Any operating or execution error is translated into a message on the control panel and an audible warning automatically disconnecting the steam generator.
Standards:
• EN 61010-1 Safety requirements for laboratory equipment.
• EN 61010-2-040 Safety requirements for laboratory equipment. Sterilizers.
• EN 61326 Electromagnetic compatibility requirements for laboratory equipment.
*Supplied without basket and without drums.
Installation not included.