Reference. 1237CO2CAN-PF
O2/CO2 Nasal Cannula for Capnography with Hydrophobic Filter and Luer-Lock Connector. Pediatric
O2/CO2 cannula for non-intubated pediatric patients, with hydrophobic filter and Luer Lock connection for continuous monitoring of exhaled CO2 during the administration of supplemental oxygen.
Description
This cannula is designed for monitoring exhaled carbon dioxide in non-intubated pediatric patients using a gas analyzer, while administering supplemental oxygen. The cannula connects the patient to the analyzer and allows for the transport of a sample of exhaled gases through the sampling tube for continuous CO2 measurement.
Its design incorporates a soft material to facilitate placement over the ears and improve comfort during use. It has a hydrophobic filter with a 0.20 µm membrane that helps protect the monitoring system from moisture and liquid entry.
Technical Specifications:
- Designed for adult patients.
- Indicated for non-intubated patients.
- Allows for continuous monitoring of exhaled CO2.
- Compatible with simultaneous administration of supplemental oxygen.
- With integrated hydrophobic filter.
- Hydrophobic membrane of 0.20 µm.
- Filtration area: 1.53 cm².
- Water inlet pressure: ≥ 3.1 bar (45 psi).
- Air flow: ≥ 3.2 l/min/cm² at 1 bar (15 psi).
- Female Luer Lock connector.
- Male Luer Lock connector for tube with 3 mm outer diameter.
- Filter burst pressure: 2 bar (29 psi).
- Cannula made of PVC.
- Filter made of rigid PVC and hydrophobic membrane.
- Individual non-sterile polyethylene packaging.
- Class IIa medical device, non-sterile.
- Latex-free product.
*Intended for use by healthcare professionals. Use in accordance with the manufacturer's instructions and the protocols established by the healthcare center.
Its design incorporates a soft material to facilitate placement over the ears and improve comfort during use. It has a hydrophobic filter with a 0.20 µm membrane that helps protect the monitoring system from moisture and liquid entry.
Technical Specifications:
- Designed for adult patients.
- Indicated for non-intubated patients.
- Allows for continuous monitoring of exhaled CO2.
- Compatible with simultaneous administration of supplemental oxygen.
- With integrated hydrophobic filter.
- Hydrophobic membrane of 0.20 µm.
- Filtration area: 1.53 cm².
- Water inlet pressure: ≥ 3.1 bar (45 psi).
- Air flow: ≥ 3.2 l/min/cm² at 1 bar (15 psi).
- Female Luer Lock connector.
- Male Luer Lock connector for tube with 3 mm outer diameter.
- Filter burst pressure: 2 bar (29 psi).
- Cannula made of PVC.
- Filter made of rigid PVC and hydrophobic membrane.
- Individual non-sterile polyethylene packaging.
- Class IIa medical device, non-sterile.
- Latex-free product.
*Intended for use by healthcare professionals. Use in accordance with the manufacturer's instructions and the protocols established by the healthcare center.