Reference. 94278K15

K15 multiparameter monitor with 15" touch screen (ECG, NIBP, PR, TEMP, RESP, SpO2)

Multifunctional patient monitor ideal for monitoring the vital physiological signs of adult, pediatric, and neonatal patients.
-51% 995,00€ 2.050,00€ (1.203,95€ VAT INCLUDED)
Buy
Secure payment
Approximate delivery time of 10 to 20 days

Description

Multifunctional patient monitor ideal for monitoring the vital physiological signs of adult, pediatric, and neonatal patients.

Features:
- Real-time recording and visualization of the following parameters:
• ECG
• Heart rhythm (PR/HR)
• Non-invasive blood pressure (NIBP/BP)
• Oxygen saturation (SpO2)
• Respiration (RESP)
• Temperature (TEMP)

Product characteristics:
- Ergonomic design.
- With intuitive user interface.
- USB port for data transfer and software update.
- 9 waveform traces on the screen.
- Windos style screen view - easy to use.
- Visual and audible alarm for physiological and technical alarms.
- Large storage capacity.
- Suitable for use with original Nellcor sensors.
- Equipped with defibrillator discharge protection.
- Equipped with resistance against interferences from the electrosurgical unit.
- Detection and inhibition of cardiac pacemaker pulse.
- Internal software: GB, DE, FR, PT, ES, IT, PL, TR, RU
- PC software GB, TI, ES.
- Compatible with Windows XP, 7, 8, 10, 11.

Technical specifications:
- ECG input dynamic range: ±(0.5~5 mVp).
- Differential input impedance: =10 MO.
- Bandwidth: 
• 0.05~150 Hz (diagnostic)
• 0.5~40 Hz (monitoring)
• 1~20 Hz (operation)
- CMRR: =90 dB ( Diagnostic) / =105 dB (Monitoring and operation).
- Sensitivity selection:  ×1/4, ×1/2, ×1, ×2, ×4 and automatic sweep speed: 6.25 mm/s, 12.5 mm/s, 25 mm/ s, 50 mm/s.
- HR measurement range: 15~350 bpm ±1% or ±2 bpm, whichever is greater.
- Pacemaker pulse detection and rejection function.

RESP:
- Measurement range: 0~120 rpm ±5% or ±2 rpm, whichever is greater.

TEMP:
- Measurement range: 21.0~50.0 °C ±0.2 °C from 25~45 °C.

NIBP (BP):
- Technique: oscillometric method.
- Typical measurement time: <30 seconds (adult cuff).
- NIBP measurement range:
• SYS: 40~275 mmHg (adult) / 40~200 mmHg (pediatric) / 40~135 mmHg (neonate).
 DIA: 10~210 mmHg (adult) / 10~150 mmHg (pediatric) / 10~95 mmHg (neonate).
 MAP: 20~230 mmHg (adult) / 20~165 mmHg (pediatric) / 20~110 mmHg (neonate).
- NIBP measurement mode: manual, automatic, STAT, multiple cycle mode.
- NIBP measurement accuracy: average difference of ±5 mmHg.
- Standard deviation: 8 mmHg.
- Automatic measurement intervals: 1-480 min.

SpO2:
- Technique: dual wavelength optical method.
- Measurement range: 0%~100% ±2% for SpO2 range 70~100%.
- PR measurement range: 30~250bpm ±2bpm or ±2%, whichever is greater.
- Low perfusion performance: as low as 0.3%.

Other specifications:
- Power supply: AC 100-240 V, 50/60 Hz, 60 VA.
- Built-in lithium battery: 11.1 V/4400 mAh.
- Display: 15-inch TFT display.
- Alarm method: 3-level audible-visual alarm.
- Network connection: Ethernet.
- Standard safety: IEC 60601-1.

Standard Accessories:
- Adult SpO2 probe.
- Adult NIBP cuff.
- SpO2 extension cable.
- ECG cable.
- Skin temperature probe.
- Power cable.
- Rechargeable lithium battery.
- Dust protective cover.
- Disposable electrode.
- Manual: GB, FR, IT, ES.
- Single-use PAI monitoring kit.

- PC software: GB, TI, ES.

Regulations and certifications:
- ISO 9001/13485 Certificate.
- CE Certificate.

Alternative products