Reference. 94278K15

K15 multiparameter monitor with 15" touch screen (ECG, NIBP, PR, TEMP, RESP, SpO2)

Multifunctional patient monitor ideal for monitoring the vital physiological signs of adult, pediatric, and neonatal patients.
-51% 995,00€ 2.050,00€ (1.203,95€ VAT INCLUDED)
Buy
Secure payment
Delivery in 10-20 days

Description

Multifunctional patient monitor ideal for monitoring the vital physiological signs of adult, pediatric, and neonatal patients.

Features:
- Real-time recording and visualization of the following parameters:
• ECG
• Heart rhythm (PR/HR)
• Non-invasive blood pressure (NIBP/BP)
• Oxygen saturation (SpO2)
• Respiration (RESP)
• Temperature (TEMP)

Product characteristics:
- Ergonomic design.
- With intuitive user interface.
- USB port for data transfer and software update.
- 9 waveform traces on the screen.
- Windos style screen view - easy to use.
- Visual and audible alarm for physiological and technical alarms.
- Large storage capacity.
- Suitable for use with original Nellcor sensors.
- Equipped with defibrillator discharge protection.
- Equipped with resistance against interferences from the electrosurgical unit.
- Detection and inhibition of cardiac pacemaker pulse.
- Internal software: GB, DE, FR, PT, ES, IT, PL, TR, RU
- PC software GB, TI, ES.
- Compatible with Windows XP, 7, 8, 10, 11.

Technical specifications:
- ECG input dynamic range: ±(0.5~5 mVp).
- Differential input impedance: =10 MO.
- Bandwidth: 
• 0.05~150 Hz (diagnostic)
• 0.5~40 Hz (monitoring)
• 1~20 Hz (operation)
- CMRR: =90 dB ( Diagnostic) / =105 dB (Monitoring and operation).
- Sensitivity selection:  ×1/4, ×1/2, ×1, ×2, ×4 and automatic sweep speed: 6.25 mm/s, 12.5 mm/s, 25 mm/ s, 50 mm/s.
- HR measurement range: 15~350 bpm ±1% or ±2 bpm, whichever is greater.
- Pacemaker pulse detection and rejection function.

RESP:
- Measurement range: 0~120 rpm ±5% or ±2 rpm, whichever is greater.

TEMP:
- Measurement range: 21.0~50.0 °C ±0.2 °C from 25~45 °C.

NIBP (BP):
- Technique: oscillometric method.
- Typical measurement time: <30 seconds (adult cuff).
- NIBP measurement range:
• SYS: 40~275 mmHg (adult) / 40~200 mmHg (pediatric) / 40~135 mmHg (neonate).
• DIA: 10~210 mmHg (adult) / 10~150 mmHg (pediatric) / 10~95 mmHg (neonate).
• MAP: 20~230 mmHg (adult) / 20~165 mmHg (pediatric) / 20~110 mmHg (neonate).
- NIBP measurement mode: manual, automatic, STAT, multiple cycle mode.
- NIBP measurement accuracy: average difference of ±5 mmHg.
- Standard deviation: 8 mmHg.
- Automatic measurement intervals: 1-480 min.

SpO2:
- Technique: dual wavelength optical method.
- Measurement range: 0%~100% ±2% for SpO2 range 70~100%.
- PR measurement range: 30~250bpm ±2bpm or ±2%, whichever is greater.
- Low perfusion performance: as low as 0.3%.

Other specifications:
- Power supply: AC 100-240 V, 50/60 Hz, 60 VA.
- Built-in lithium battery: 11.1 V/4400 mAh.
- Display: 15-inch TFT display.
- Alarm method: 3-level audible-visual alarm.
- Network connection: Ethernet.
- Standard safety: IEC 60601-1.

Standard Accessories:
- Adult SpO2 probe.
- Adult NIBP cuff.
- SpO2 extension cable.
- ECG cable.
- Skin temperature probe.
- Power cable.
- Rechargeable lithium battery.
- Dust protective cover.
- Disposable electrode.
- Manual: GB, FR, IT, ES.
- Single-use PAI monitoring kit.

- PC software: GB, TI, ES.

Regulations and certifications:
- ISO 9001/13485 Certificate.
- CE Certificate.

Alternative products