Reference. 400130697
MB 400 Touch monopolar-bipolar diathermy electrosurgical unit 400 Watt
High frequency 400W electrosurgical unit, suitable for precision mono, bipolar and microsurgery.
Personal advice
Description
The Diatermo MB 400 Touch electrosurgical unit is a new generation electrosurgery equipment that allows two surgeons to work simultaneously, suitable for microsurgery and precision surgery in monopolar and bipolar mode.
Features:
- Simultaneous activation of monopolar and bipolar.
- Contemporary dual monopolar.
- Contemporary dual bipolar.
- Power control based on impedance.
- Activation power with pedal and/or handpiece.
- Control of neutral electrode-patient contact.
- TUR saline solution cutting function.
- BLEND modular cut under wet conditions.
- Vessel sealing for clamping vessels up to 7 mm.
- Possibility of use for minimally invasive surgery.
- Monopolar / bipolar functions.
- Automatic start / automatic stop in bipolar mode.
- Sound intensity adjustment.
The neutral electrode connection is constantly monitored: if a split neutral plate is used, the device will control the contact between the patient and the electrode.
Allows for operations without diverting attention from the intervention area thanks to the possibility of changing functions and configuring the power source from the handpiece.
In addition, with just the touch of a finger, you can choose between a white or black screen, how to customize and save your work settings, change the cutting or coagulation power and manage each function of the device.
Recommended for gastroenterology, general surgery, neurosurgery, orthopedics, pediatric surgery, plastic surgery, thoracic surgery, ETU, urology, dermatology, endoscopy, gynecology, otolaryngology, pulmonology, vascular surgery or veterinary.
Technical specifications:
- Maximum PURE CUT output power: 400 W - 300 Ohm.
- Maximum BLEND output power: 250 W - 300 Ohm.
- Maximum ENHANCED output power: 250 W - 300 Ohm.
- Maximum FORCED COAG output power: 150 W - 150 Ohm.
- Maximum SOFT COAG output power: 150 W - 200 Ohm.
- Maximum TUR BIPOLAR output power: 300 W - 200 Ohm.
- Maximum BIPOLAR CUT output power: 150 W - 100 Ohm.
- Maximum BIPOLAR COAG output power: 150 W - 50 Ohm.
- Maximum BIPOLAR SEALING output power: 250 W - 50 Ohm.
- Maximum FULGURATION output power: 100 W - 500 Ohm.
- Working frequency: 360 kHz.
- Patient circuit: F.
- Selectable input voltage: 100-240 Vac.
- Network frequency: 50-60 Hz.
- Input electrical voltage: 1000 VA.
- Size WxHxD: 450 x 200 x 420 mm.
- Weight: 15.5 kg.
- Controls: Patient circuit/plate monitoring, output power monitoring, self-check control, high frequency leakage current control, network fluctuation compensation.
- Safety: EN60601-1, EN60601-1-2, EN60601-2-2, Electrical class: I CF, MDD 93/42/EC Class: II b.
Standard accessories:
- Flexible steel neutral plate with cable.
- 5 m power cable.
- Reusable handle with switches.
- Waterproof pedal.
- 3 blade electrodes - 16 cm.
- 3 blade electrodes - 7 cm.
- 3 ball electrodes Ø 4 mm - 6 cm.
Features:
- Simultaneous activation of monopolar and bipolar.
- Contemporary dual monopolar.
- Contemporary dual bipolar.
- Power control based on impedance.
- Activation power with pedal and/or handpiece.
- Control of neutral electrode-patient contact.
- TUR saline solution cutting function.
- BLEND modular cut under wet conditions.
- Vessel sealing for clamping vessels up to 7 mm.
- Possibility of use for minimally invasive surgery.
- Monopolar / bipolar functions.
- Automatic start / automatic stop in bipolar mode.
- Sound intensity adjustment.
The neutral electrode connection is constantly monitored: if a split neutral plate is used, the device will control the contact between the patient and the electrode.
Allows for operations without diverting attention from the intervention area thanks to the possibility of changing functions and configuring the power source from the handpiece.
In addition, with just the touch of a finger, you can choose between a white or black screen, how to customize and save your work settings, change the cutting or coagulation power and manage each function of the device.
Recommended for gastroenterology, general surgery, neurosurgery, orthopedics, pediatric surgery, plastic surgery, thoracic surgery, ETU, urology, dermatology, endoscopy, gynecology, otolaryngology, pulmonology, vascular surgery or veterinary.
Technical specifications:
- Maximum PURE CUT output power: 400 W - 300 Ohm.
- Maximum BLEND output power: 250 W - 300 Ohm.
- Maximum ENHANCED output power: 250 W - 300 Ohm.
- Maximum FORCED COAG output power: 150 W - 150 Ohm.
- Maximum SOFT COAG output power: 150 W - 200 Ohm.
- Maximum TUR BIPOLAR output power: 300 W - 200 Ohm.
- Maximum BIPOLAR CUT output power: 150 W - 100 Ohm.
- Maximum BIPOLAR COAG output power: 150 W - 50 Ohm.
- Maximum BIPOLAR SEALING output power: 250 W - 50 Ohm.
- Maximum FULGURATION output power: 100 W - 500 Ohm.
- Working frequency: 360 kHz.
- Patient circuit: F.
- Selectable input voltage: 100-240 Vac.
- Network frequency: 50-60 Hz.
- Input electrical voltage: 1000 VA.
- Size WxHxD: 450 x 200 x 420 mm.
- Weight: 15.5 kg.
- Controls: Patient circuit/plate monitoring, output power monitoring, self-check control, high frequency leakage current control, network fluctuation compensation.
- Safety: EN60601-1, EN60601-1-2, EN60601-2-2, Electrical class: I CF, MDD 93/42/EC Class: II b.
Standard accessories:
- Flexible steel neutral plate with cable.
- 5 m power cable.
- Reusable handle with switches.
- Waterproof pedal.
- 3 blade electrodes - 16 cm.
- 3 blade electrodes - 7 cm.
- 3 ball electrodes Ø 4 mm - 6 cm.