Reference. 1208TPT01
Universal bipolar electrosurgical plate with gel, without cable
Universal size two-pole electrosurgical plate with a gel-coated layer for easy placement. Supplied without connection cable to electrosurgery unit.
Personal advice
Description
This plate allows the dissipation of the electrical current generated by an electrosurgery unit during surgery. When placed on the skin, it acts as a return electrode, closing the circuit and dispersing the current flow produced by the electrosurgery unit. In this way, the electrical charge is optimally distributed, preventing burns or accidental discharges during the procedure.
To use it, a compatible connection cable must be purchased (Ref. 1208TCC12) (not included and at an additional cost).
General features
- Neck with insulating adhesive to prevent current leakage
- Made without biological components, phthalates or latex
- Suitable for traditional surgical interventions
- Distributed without electrosurgery unit connector cable
- Produced in accordance with RoHS and ISO 13485
- Classified as group 1, class A product, according to EN 55011/CISPR 11 standard
- In compliance with the electrical safety standards EN IEC 60601-2-2:2018 and ANSI/AAMI HF-18
- Classified as class IIb medical device according to regulation (EU) 2017/745
Technical specifications
- Model: bipolar
- Compatibility: universal
- Weight limit: > 5 kg
- Width: 163.5 mm
- Height/length: 117 mm
- Total: 168 cm2
- Conductive surface: 105 cm2
- Hydrogel thickness: 0.69 mm gel + aluminum
- Expiry: 3 years from the date of manufacture
Materials
- Support material: flexible white PE foam, closed cell structure (waterproof), with biocompatible acrylic adhesive
- Conductive area: aluminum/PET complex with biocompatible acrylic base hydrogel
- Protector: PET
Electrical properties (ANSI/AAMI EC12)
- Temperature increase (IEC 60601-2-2, cl. 201.15.101.5): < 6ºC
- Contact impedance (IEC 60601-2-2, cl. 201.15.101.6): < 50 Ω
Biocompatibility
- ISO 10993-5: non-cytotoxic
- ISO 10993-10: non-sensitizing
- ISO 10993-10: negative intercutaneous irritation test
To use it, a compatible connection cable must be purchased (Ref. 1208TCC12) (not included and at an additional cost).
General features
- Neck with insulating adhesive to prevent current leakage
- Made without biological components, phthalates or latex
- Suitable for traditional surgical interventions
- Distributed without electrosurgery unit connector cable
- Produced in accordance with RoHS and ISO 13485
- Classified as group 1, class A product, according to EN 55011/CISPR 11 standard
- In compliance with the electrical safety standards EN IEC 60601-2-2:2018 and ANSI/AAMI HF-18
- Classified as class IIb medical device according to regulation (EU) 2017/745
Technical specifications
- Model: bipolar
- Compatibility: universal
- Weight limit: > 5 kg
- Width: 163.5 mm
- Height/length: 117 mm
- Total: 168 cm2
- Conductive surface: 105 cm2
- Hydrogel thickness: 0.69 mm gel + aluminum
- Expiry: 3 years from the date of manufacture
Materials
- Support material: flexible white PE foam, closed cell structure (waterproof), with biocompatible acrylic adhesive
- Conductive area: aluminum/PET complex with biocompatible acrylic base hydrogel
- Protector: PET
Electrical properties (ANSI/AAMI EC12)
- Temperature increase (IEC 60601-2-2, cl. 201.15.101.5): < 6ºC
- Contact impedance (IEC 60601-2-2, cl. 201.15.101.6): < 50 Ω
Biocompatibility
- ISO 10993-5: non-cytotoxic
- ISO 10993-10: non-sensitizing
- ISO 10993-10: negative intercutaneous irritation test