Reference. 1190AB7800013TACTIL

12" K12 multiparametric touch monitor (ECG, NIBP, PR, TEMP, RESP, SpO2)

12" K12 multiparametric touch monitor (ECG, NIBP, SpO2, PR, RESP, and TEMP)
Personalized attention
Personal advice
-27% 848,00€ 1.166,00€ (1.026,08€ VAT INCLUDED)
Buy
Secure payment
Product in stock. Estimated delivery 48-72 hours.

Description

Cardioline
A multiparametric monitor designed with a 12.1" touchscreen with LED backlight that displays 9 simultaneous traces and up to a maximum of 13. It allows monitoring of ECG, NIBP, SpO2, HR, respiration and temperature parameters in both adult and pediatric and neonatal patients.

It incorporates the Standard HL-7 Protocol to connect the equipment to the information system of your medical center. This protocol enables a bed-to-bed view that can be consulted through the monitoring center.

Versatile clinical calculations suitable for application:
- Hemodynamic
- Respiratory
- Oxygenation
- Drug concentration
- Kidney function

Features:
- Customizable NIBP measurement with cycles of up to 5 periods.
- Incorporates updatable software that allows data export.
- Has acoustic alarms with 3 adjustable audio levels and a 360° visible light indicator.
- Li-Ion battery for up to 3 hours of continuous monitoring.
- Integrated 3-channel printer.
- Ample storage and memory capacity.

- 2-year warranty.

Technical specifications: 
- ECG:
    - Dynamic input range: ±(0.5-5 mVp).
    - Input differential impedance: ≥10 MΩ.
    - Bandwidth:
        - 0.05-150 Hz (diagnostic)
        - 0.5-40 Hz (monitoring)
        - 1-20 Hz (operation)
    - CMRR:
        - ≥90 dB (diagnostic)
        - ≥105 dB (monitoring and operation)
    - Sensitivity selection: x1/4, x1/2, x1, x2, x4 and Auto.
    - Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s.
    - Heart rate measurement range: 15-350 bpm.
    - Heart rate accuracy: ±1% or ±2 bpm, whichever is greater.
    - Alarm delay time: ≤10 sec.
    - Pacemaker pulse detection and rejection function.
- Respiration: 
    - Measurement range: 0-120 rpm.
    - Measurement accuracy: ±5% or ±2 rpm, whichever is greater.
- Temperature: 
    - Measurement range: 21.0-50.0 °C.
    - Measurement accuracy: ±0.2 °C between 25-4 °C.
- NIBP (NIBP):
    - Method: oscillometric.
    - Pressure measurement accuracy: ±3 mmHg.
    - Typical measurement time: <30 seconds (adult cuff).
    - NIBP SYS measurement range:
        - Adult: 40-275 mmHg.
        - Pediatric: 40-200 mmHg.
        - Neonate: 40-135 mmHg.
    - NIBP DIA measurement range:
        - Adult: 10-210 mmHg.
        - Pediatric: 10-150 mmHg.
        - Neonate: 10-95 mmHg.
    - NIBP MAP measurement range:
        - Adult: 20-230 mmHg.
        - Pediatric: 20-165 mmHg.
        - Neonate: 20-110 mmHg.
    - NIBP measurement accuracy:
        - Mean difference: ±5 mmHg.
        - Standard deviation: 8 mmHg.
    - NIBP measurement modes: Manual, Auto, STAT, Multi-cycle Modes.
    - Auto measurement intervals: 1-480 min.
- SpO2: 
    - Method: Optical with two wavelengths.
    - Measurement range: 0-100%.
    - Measurement accuracy: never greater than 2% for the SpO2 range between 70-100%.
    - HR measurement range: 30-250 bpm.
    - Measurement accuracy: ±2 bpm or ±2%, whichever is greater.
    - Low perfusion performance: as low as 0.3%.
-Cardiac Output (C.O) (optional):
    - Range of blood temperature measurement range: 0%- 100%.
    - R
ange of perfusion temperature measurement: 0 - 20°C, accuracy: ±0.5°C.
    - Measurement range: 0.2 - 20 L/min.
    - Measurement accuracy: ±0.2 L/min or ±10%, whichever is greater.
-EtCO2 (optional):
    
- Technique: Infrared optical method.
    - Sampling mode: Sidestream or Mainstream.
    - Measurement range: 0 - 150mmHg.
    - Measurement accuracy:
            0 - 40mmHg ± 2mmHg.
           41 - 70mmHg ± 5% of the reading.
           71 - 100mmHg  ± 8% of reading.
           101 - 150mmHg ± 10% of reading.
    - Flow: 50ml/min. ± 10ml/min.(Sidestream).
- IBP (IBP) (optional):
     
- Technique: Strain gauge transducer.
     - Input sensitivity: 5μV/V/mmHg.
     - Measurement range: -50 - 300mmHg.
     - Measurement accuracy: ± 2% or ±4 mmHg, whichever is greater.
     - Measurement positions: ART, RAP, PA, LAP, CVP, ICP, AUXP1, AUXP2.
     - Zero calibration.

- Central monitoring station:
    - EEG sensitivity: ±400 μV.
    - Noise level: <2 μVp-p, < 0.4 μVrms (1-250 Hz).
    - CMRR: >140 dB.
    - Input impedance: >50 Mohm.
    - CSI and update: 0-100 filter: 6-24 Hz, 1 sec. update.
    - EMG%:
        - 0-100 (logarithmic)
        - Filter: 75-85 Hz, 1 sec. update
    - BS%: 0-100 filter: 2-42 Hz, 1 sec. update.
- Power supply: AC 100-240 V, 50/60 Hz, 60 VA.
- Built-in lithium battery: 11.1 V, 4400 mAh.
- Alarm types: visual alarm and 3 audio levels.
- Network: Ethernet.

- Standard configuration: ECG, RESPIRATION, SpO2, HR, NIBP, TEMPERATURE.
- Options: IBP, EtCO2, Nellcor SpO2, SunTech NIBP, Cardiac Output, 12-Lead ECG, Multi-Gas, Cerebral State Monitoring, Monitoring Center, Touch Screen.

2-year warranty.

Includes: 
- Adult SpO2 sensor.
- Adult NIBP cuff.
- ECG cable.
- Temperature sensor.

Optional accessories with additional cost:
- Capnography module.
- Invasive blood pressure (IBP) module.
- Nellcor SpO2 module.
- SunTech NIBP module.
- Cardiac output. 
- 12-lead ECG. 
- Cerebral state monitoring.

Alternative products