Reference. 4024STE23T

Autoclave 29 liters class B IcanClave, without printer

29 liter Class B Autoclave, Without Printer

29 liter Class B Autoclave with USB and double safety lock, with a longer length that allows sterilizing instruments up to 600mm long. Technical Specifications • Nominal Voltage: 220-110 V; 50/60 Hz • Nominal Power: 2500 W • Chamber Dimensions:...
Personalized attention
Personal advice
Autoclave 29 liters class B IcanClave, without printer
Autoclave 29 liters class B IcanClave, without printer
Autoclave 29 liters class B IcanClave, without printer
Autoclave 29 liters class B IcanClave, without printer
Autoclave 29 liters class B IcanClave, without printer
Autoclave 29 liters class B IcanClave, without printer
3.300,00€ (3.993,00€ VAT INCLUDED)
Buy
Secure payment
Approximate delivery time 30 to 60 days

Description

29 liter Class B Autoclave, Without Printer

29 liter Class B Autoclave with USB and double safety lock, with a longer length that allows sterilizing instruments up to 600mm long.

Technical Specifications
• Nominal Voltage: 220-110 V; 50/60 Hz
• Nominal Power: 2500 W
• Chamber Dimensions: 247 x 625mm
• Tray Measurements: 
          Tray 1: 185x570 mm
          Tray 2: 213x570 mm
          Tray 3: 227x570 mm
• Sterilization Temperature: 121 °C / 134 °C
• Operating Relative Humidity: Max. 80%, non-condensing
• External Dimensions: 480 x 455 x 850 mm
• Net Weight: 58 kg
• Operating Atmospheric Pressure: 76kPa / 106 kPa
• Maximum Noise Level: <70 dB

Components

• Door with automatic locking system
• Opening and closing handle
• LCD Screen
• Control Panel
• Distilled Water Tank
• USB Port
• Key for draining distilled and used water
• Safety Valve
• Ventilation Grid
• Power Cable

Included Accessories
• 3 Stainless steel instrument trays 
Tray base
Tray extraction handle
2 Drain Hoses
Door adjustment tool
Instruction Manual

Installation
• The sterilizer should be placed on a flat, level surface with a minimum load capacity of 60 Kg
• To ensure proper air circulation, leave at least 10cm free space around the device on the sides and 20cm on the top
• The sterilizer should be located in a properly ventilated enclosure
• Do not install the sterilizer near sources of water and/or heat
• Do not cover the air outlet grill of the condenser fan, nor block the side outlets

Regulations

This Icanclave sterilizer has been designed and manufactured in accordance with the following directives and standards:
Directive 97/23 / EC on pressure equipment
Directive 93/42 / EEC on class II-a medical devices
Standard EN13060 on small steam sterilizers
Standard EN61010-1 on laboratory equipment safety
Standard EN 61010-2-040 on safety for medical material sterilizers
Standard EN 61326-1 on electromagnetic compatibility