Reference. 130810145
Advanced Harp Diagnostic Audiometer
Advanced diagnostic device designed to perform precise and efficient audiometric tests.
Personal advice
Description
The Harp Plus audiometer offers a wide range of tests, including pure tone audiometry, logoaudiometry, and special tests such as ABLB, SISI, Stenger, DLI, and tonal decay.
Features:
- Versatility: Performs air, bone, and vocal audiometries, standard audiometries, including pure tones and speech, automated Hughson-Westlake tests, ABLB, SISI, Stenger, DLI, Tonal Decay, 2-channel Master Hearing Aid.
- Color screen: It has a 4.3" TFT LCD graphic screen that displays the full audiogram during the exam.
- Connectivity: It easily integrates with NOAH and Maestro software through a USB connection, without the need for additional drivers.
Advanced functionalities:
- 2-channel master hearing aid. It allows the evaluation of hearing aids.
- Automated audiometry. Includes the Hughson-Westlake method for automatic threshold tests.
- Masking. Offers options for narrow band noise (NBN), white noise (WN), and speech noise (SN).
The Harp Plus combines high-level features with ease of use and portability, making it ideal for a wide range of professionals, from hearing aid dispensers to audiologists in clinics and hospitals. Its compact dimensions (32 x 32 x 9 cm) and light weight (1.8 kg without printer) make it easily transportable.
The audiometer can operate independently or be controlled by a PC, offering flexibility in its use. This feature, along with its intuitive interface, makes it a versatile tool for different clinical environments.
Technical specifications:
- Available signals:
• Stimulus: pure tone, warble tone
• 2 external inputs for speech audiometry.
• Microphone input for live speech audiometry.
• Masking: NBN, WN, SN.
- Signal specifications:
• Attenuator step: 1 and 5 dB.
• Presentation: Continuous, pulsed (0.5, 1 and 2 Hz).
• Warble: 5 Hz sinusoidal wave modulator signal.
- Available transducer outputs:
• AC: TDH-39 / DD45 headphones, ER-3 / IP30 insert headphones.
• BC: B-71 bone vibrator.
• Free field Insert masking earphone: IME-100.
- Available tests:
•Pure tone audiometry.
•Automatic threshold (modified Hughsone-Westlake).
•Speech audiometry (2 channels).
•ABLB.
•SISI: automatic scoring; 1 dB increment (5 dB for familiarization).
•Stenger, with pure tone or speech stimulation.
•Tone decay, with a duration of 60 or 120 sec.
•DLI, with increments between 0 and 5 dB.
• A2 independent channel master hearing aid.
- Patient-operator communication:
• Talk over: built-in or external microphone.
• Talk back: through the built-in speaker or monitoring headphones (included); patient microphone included.
• Patient response trigger.
- Monitoring signal:
• Both channels monitored through the built-in speaker or monitoring headphones (included).
- Internal Flash memory:
•Used to store speech material (.wav format).
• Capacity: 4GB (more than 6 hours of speech).
• Speech material upload: through the ATIT software (included).
- Printer:
•Optional integrated thermal printer.
• Paper size: 112 mm.
- Internal database:
• Up to 100 patients with AC and BC thresholds (pure tone exams only).
- Calibration:
• Validity: 12 months.
• All parameters configured through the device software.
- Computer interface:
• Connection: USB (driverless).
• Compatible software: Inventis Maestro.
- Hybrid technology:
• Description: Harp can be controlled as a stand-alone audiometer or PC-controlled.
• Requires the Inventis Maestro software.
- Screen
• Live display of the graph of all tests.
• Type: color graphic LCD TFT.
• Size: 4.3" diagonal, 95 mm x 54 mm.
• Resolution: 480 x 272.
- Power supply:
• Without built-in printer: Maximum consumption: 8 Watts. Power supply: 6V, 2A cont., through a 100-240 Vac 50/60 Hz medical grade external power supply.
•With built-in printer: Maximum consumption: 25 Watts. Power supply: 6V, 4.16A cont., through a 100-240 Vac 50/60 Hz medical grade external power supply.
- Mechanics:
•Without built-in printer: Size (WxDxH): 32 x 32 x 9 cm / 12.6 x 12.6 x 3.5 inches. Weight: 1.8 Kg / 4.0 lbs.
•With built-in printer: Size (WxDxH): 32 x 39 x 9 cm / 12.6 x 15.4 x 3.5 inches. Weight: 2.3 Kg / 5.0 lbs.
Features:
- Versatility: Performs air, bone, and vocal audiometries, standard audiometries, including pure tones and speech, automated Hughson-Westlake tests, ABLB, SISI, Stenger, DLI, Tonal Decay, 2-channel Master Hearing Aid.
- Color screen: It has a 4.3" TFT LCD graphic screen that displays the full audiogram during the exam.
- Connectivity: It easily integrates with NOAH and Maestro software through a USB connection, without the need for additional drivers.
Advanced functionalities:
- 2-channel master hearing aid. It allows the evaluation of hearing aids.
- Automated audiometry. Includes the Hughson-Westlake method for automatic threshold tests.
- Masking. Offers options for narrow band noise (NBN), white noise (WN), and speech noise (SN).
The Harp Plus combines high-level features with ease of use and portability, making it ideal for a wide range of professionals, from hearing aid dispensers to audiologists in clinics and hospitals. Its compact dimensions (32 x 32 x 9 cm) and light weight (1.8 kg without printer) make it easily transportable.
The audiometer can operate independently or be controlled by a PC, offering flexibility in its use. This feature, along with its intuitive interface, makes it a versatile tool for different clinical environments.
Technical specifications:
- Available signals:
• Stimulus: pure tone, warble tone
• 2 external inputs for speech audiometry.
• Microphone input for live speech audiometry.
• Masking: NBN, WN, SN.
- Signal specifications:
• Attenuator step: 1 and 5 dB.
• Presentation: Continuous, pulsed (0.5, 1 and 2 Hz).
• Warble: 5 Hz sinusoidal wave modulator signal.
- Available transducer outputs:
• AC: TDH-39 / DD45 headphones, ER-3 / IP30 insert headphones.
• BC: B-71 bone vibrator.
• Free field Insert masking earphone: IME-100.
- Available tests:
•Pure tone audiometry.
•Automatic threshold (modified Hughsone-Westlake).
•Speech audiometry (2 channels).
•ABLB.
•SISI: automatic scoring; 1 dB increment (5 dB for familiarization).
•Stenger, with pure tone or speech stimulation.
•Tone decay, with a duration of 60 or 120 sec.
•DLI, with increments between 0 and 5 dB.
• A2 independent channel master hearing aid.
- Patient-operator communication:
• Talk over: built-in or external microphone.
• Talk back: through the built-in speaker or monitoring headphones (included); patient microphone included.
• Patient response trigger.
- Monitoring signal:
• Both channels monitored through the built-in speaker or monitoring headphones (included).
- Internal Flash memory:
•Used to store speech material (.wav format).
• Capacity: 4GB (more than 6 hours of speech).
• Speech material upload: through the ATIT software (included).
- Printer:
•Optional integrated thermal printer.
• Paper size: 112 mm.
- Internal database:
• Up to 100 patients with AC and BC thresholds (pure tone exams only).
- Calibration:
• Validity: 12 months.
• All parameters configured through the device software.
- Computer interface:
• Connection: USB (driverless).
• Compatible software: Inventis Maestro.
- Hybrid technology:
• Description: Harp can be controlled as a stand-alone audiometer or PC-controlled.
• Requires the Inventis Maestro software.
- Screen
• Live display of the graph of all tests.
• Type: color graphic LCD TFT.
• Size: 4.3" diagonal, 95 mm x 54 mm.
• Resolution: 480 x 272.
- Power supply:
• Without built-in printer: Maximum consumption: 8 Watts. Power supply: 6V, 2A cont., through a 100-240 Vac 50/60 Hz medical grade external power supply.
•With built-in printer: Maximum consumption: 25 Watts. Power supply: 6V, 4.16A cont., through a 100-240 Vac 50/60 Hz medical grade external power supply.
- Mechanics:
•Without built-in printer: Size (WxDxH): 32 x 32 x 9 cm / 12.6 x 12.6 x 3.5 inches. Weight: 1.8 Kg / 4.0 lbs.
•With built-in printer: Size (WxDxH): 32 x 39 x 9 cm / 12.6 x 15.4 x 3.5 inches. Weight: 2.3 Kg / 5.0 lbs.