Reference. 1187HJB007
Zuzi Model 4310/3 Visible Spectrophotometer
The Zuzi 4310/3 spectrophotometer stands out for its precision, versatility, and ease of use, becoming an indispensable tool for laboratories that require reliable and efficient results in spectrophotometric analysis.
Description
The Zuzi model 4310/3 visible spectrophotometer is a high-precision instrument designed for spectrophotometric measurement and analysis in laboratories of various sectors, including life sciences, materials, health, education, environmental protection, and quality control in chemical, pharmaceutical, metallurgical, and textile industries.
Characteristics:
- Single beam optical system that guarantees reliable and reproducible results.
- Light source: tungsten lamp.
- Detector: silicon photodiode.
- Wavelength range: 320-1100 nm, suitable for applications in the visible spectrum.
- Spectral bandwidth: 4 nm, ideal for precise analysis.
- 5-inch color TFT LCD touchscreen, which facilitates data visualization and menu navigation.
- Manual 10 mm cuvette holder with capacity for 4 positions, allowing simultaneous analysis of several samples.
- Integrated functions: photometry test, quantitative test, wavelength scanning, file management, system utilities, and performance verification.
- Communication interface: RS232 and USB, which facilitates connection with computers and peripherals.
- Power supply: 100-240V AC, 50/60Hz, 75W.
- Dimensions: 456 × 360 × 185 mm.
- Weight: 10.5 kg.
- The optimized design of the optical system and the cast aluminum base, together with the molded plastic housing, provide great precision, resistance, and durability.
- Offers better wavelength precision and reproducibility, as well as noise reduction thanks to its patented control mechanism.
- The high-resolution touchscreen ensures an intuitive user experience and excellent visualization effect.
- Includes auto-calibration and preheating countdown when turning on the equipment, which speeds up the start of measurements.
- Allows advanced file management and automatic wavelength adjustment.
- Can be connected to a printer for direct output of results.
- Includes the EasyUV Basic software for computer and is compatible with the optional EasyUV software (not included).
- IQ/OQ/PQ protocols available for validation in regulated environments.
The Zuzi 4310/3 is widely used in research laboratories, quality control, clinical diagnosis, environmental analysis, and industrial development. It allows quantitative and qualitative analysis, determination of compound concentration, identification of substances, purity studies, and process control, among other applications.
Functions:
- Photometry:
• Conversion A/%T/E.
• The results can be recorded, renamed, deleted, saved, and printed.
- Quantification:
• Single wavelength, dual wavelength (difference, ratio).
• Three ways to set a standard curve (entering coefficients, measuring 2 to 10 standard samples, or entering the absorbance values and concentration of standard samples).
• Three adjustment methods (zero linear, linear, quadratic).
• Standard curves can be saved and loaded.
• 19 common concentration units built-in and user-defined units (up to 8 characters).
• The results can be recorded, renamed, deleted, saved, and printed.
- Spectrum:
• The scan speed is optional (low, medium, high).
• The scan interval is optional (0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0nm).
• The display mode A/%T can be changed.
• Automatic peak search.
• Point by point view (peak).
• Adaptable and modifiable coordinates.
• The curves and data can be deleted, saved, and printed.
- Files:
• Files can be deleted, renamed, batch import/export, converted to .txt and .csv format.
- System:
• System calibration (dark current, wavelength, system baseline).
• Light source management (light source switch, timing).
• Clock.
• Memory management (storage status display, formatting).
• Six languages can be chosen (Spanish, English, French, Portuguese, German, Simplified Chinese).
• General settings (tone, brightness, close screen after, sample holder).
• Reset default values.
• About (system information).
- Performance verification:
• Wavelength accuracy
• Photometric accuracy
• Stray light
• Noise
• Dark noise
• Stability
• Bandwidth
Technical specifications:
- Optical system: Single beam, 1200 lines/mm grating.
- Wavelength range: 320-1100 nm.
- Wavelength accuracy: ±0.5 nm.
- Wavelength reproducibility: ≤0.2 nm.
- Wavelength resolution: 0.1 nm.
- Wavelength swing speed: 10000 nm/min.
- Scanning speed: 20-4200 nm/min.
- Light source: Tungsten lamp.
- Spectral bandwidth: 4 nm.
- Detector: Silicon photodiode.
- Photometric range: -0.3-3 A, 0-200 %T, 0-9999.9 C.
- Modes: Photometry, quantification, spectrum.
- Sample compartment: Manual drawer holder for 4 10mm cuvettes.
- Display: 5-inch color TFT touchscreen.
- Storage: 236 KB (internal memory), unlimited via external USB.
- Interface: RS232 serial port × 1 (printer), USB-A × 1 (USB memory/ USB printer), USB-B × 1 (PC).
- Power supply: 100-240 VAC, 50/60 Hz, 75 W.
- Dimensions (LxWxH): 450x370x187 mm.
- Weight: 10.5 kg.
Characteristics:
- Single beam optical system that guarantees reliable and reproducible results.
- Light source: tungsten lamp.
- Detector: silicon photodiode.
- Wavelength range: 320-1100 nm, suitable for applications in the visible spectrum.
- Spectral bandwidth: 4 nm, ideal for precise analysis.
- 5-inch color TFT LCD touchscreen, which facilitates data visualization and menu navigation.
- Manual 10 mm cuvette holder with capacity for 4 positions, allowing simultaneous analysis of several samples.
- Integrated functions: photometry test, quantitative test, wavelength scanning, file management, system utilities, and performance verification.
- Communication interface: RS232 and USB, which facilitates connection with computers and peripherals.
- Power supply: 100-240V AC, 50/60Hz, 75W.
- Dimensions: 456 × 360 × 185 mm.
- Weight: 10.5 kg.
- The optimized design of the optical system and the cast aluminum base, together with the molded plastic housing, provide great precision, resistance, and durability.
- Offers better wavelength precision and reproducibility, as well as noise reduction thanks to its patented control mechanism.
- The high-resolution touchscreen ensures an intuitive user experience and excellent visualization effect.
- Includes auto-calibration and preheating countdown when turning on the equipment, which speeds up the start of measurements.
- Allows advanced file management and automatic wavelength adjustment.
- Can be connected to a printer for direct output of results.
- Includes the EasyUV Basic software for computer and is compatible with the optional EasyUV software (not included).
- IQ/OQ/PQ protocols available for validation in regulated environments.
The Zuzi 4310/3 is widely used in research laboratories, quality control, clinical diagnosis, environmental analysis, and industrial development. It allows quantitative and qualitative analysis, determination of compound concentration, identification of substances, purity studies, and process control, among other applications.
Functions:
- Photometry:
• Conversion A/%T/E.
• The results can be recorded, renamed, deleted, saved, and printed.
- Quantification:
• Single wavelength, dual wavelength (difference, ratio).
• Three ways to set a standard curve (entering coefficients, measuring 2 to 10 standard samples, or entering the absorbance values and concentration of standard samples).
• Three adjustment methods (zero linear, linear, quadratic).
• Standard curves can be saved and loaded.
• 19 common concentration units built-in and user-defined units (up to 8 characters).
• The results can be recorded, renamed, deleted, saved, and printed.
- Spectrum:
• The scan speed is optional (low, medium, high).
• The scan interval is optional (0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0nm).
• The display mode A/%T can be changed.
• Automatic peak search.
• Point by point view (peak).
• Adaptable and modifiable coordinates.
• The curves and data can be deleted, saved, and printed.
- Files:
• Files can be deleted, renamed, batch import/export, converted to .txt and .csv format.
- System:
• System calibration (dark current, wavelength, system baseline).
• Light source management (light source switch, timing).
• Clock.
• Memory management (storage status display, formatting).
• Six languages can be chosen (Spanish, English, French, Portuguese, German, Simplified Chinese).
• General settings (tone, brightness, close screen after, sample holder).
• Reset default values.
• About (system information).
- Performance verification:
• Wavelength accuracy
• Photometric accuracy
• Stray light
• Noise
• Dark noise
• Stability
• Bandwidth
Technical specifications:
- Optical system: Single beam, 1200 lines/mm grating.
- Wavelength range: 320-1100 nm.
- Wavelength accuracy: ±0.5 nm.
- Wavelength reproducibility: ≤0.2 nm.
- Wavelength resolution: 0.1 nm.
- Wavelength swing speed: 10000 nm/min.
- Scanning speed: 20-4200 nm/min.
- Light source: Tungsten lamp.
- Spectral bandwidth: 4 nm.
- Detector: Silicon photodiode.
- Photometric range: -0.3-3 A, 0-200 %T, 0-9999.9 C.
- Modes: Photometry, quantification, spectrum.
- Sample compartment: Manual drawer holder for 4 10mm cuvettes.
- Display: 5-inch color TFT touchscreen.
- Storage: 236 KB (internal memory), unlimited via external USB.
- Interface: RS232 serial port × 1 (printer), USB-A × 1 (USB memory/ USB printer), USB-B × 1 (PC).
- Power supply: 100-240 VAC, 50/60 Hz, 75 W.
- Dimensions (LxWxH): 450x370x187 mm.
- Weight: 10.5 kg.