Reference. 1090DA-RL12MAR
Rescue Life 7 Defibrillator-Monitor, with 12 ECG channels, AED and printer
Defibrillation and monitoring equipment designed for emergency situations. With manual and automatic defibrillation system, consultative mode, 12-channel electrocardiogram analysis and integrated printer.
Personal advice
Description
The Rescue Life 7 is a state-of-the-art defibrillation and cardiac monitoring device that provides life support in cases of medical urgency or emergency. Made from durable, high-quality materials, it has been designed with an intuitive interface that makes it easy and quick to use in critical situations. It has an ergonomic handle built into the top and only includes lightweight components for comfortable transportation. Moreover, it has a battery with over 5 hours of autonomy and includes reusable paddles for adult and pediatric patients, so it is equipped with all the necessary material for professional medical assistance.
Its measurement systems have been configured according to the standards set by various directives in terms of medical accuracy, so the accuracy and reliability of its readings are guaranteed. Likewise, its automatic external defibrillation modality adheres to the recommendations specified in 2015 by the European Resuscitation Council. On the other hand, its monitoring systems are equipped with innovative software that allows storing up to 300 hours of ECG reading and automatically controls the device's pressure, thus ensuring patient safety during the measurement process. For all these reasons and the 2-year warranty it offers to the user, the Rescue Life 7 has positioned itself in the market as one of the most versatile, economical, and effective options for defibrillation.
General characteristics
- Robust and resistant device, designed for intense activity environments
- Ergonomic, intuitive, and easy-to-use design
- Reduced weight for comfortable transportation
- Illuminated buttons for better visibility
- Materials and finishes of the highest quality
- Internal self-test system with results printing to check the status of the equipment
- Up to 5 hours of autonomy in case of continuous monitoring
- Easily configurable and customizable operation
- Automatic detection of the ECG signal in diagnostic and monitoring modes
- Includes reusable defibrillation paddles and single-use adult electrodes
- Limited maximum inflation thanks to internal protection software to ensure patient safety
- Equipped with an additional redundant safety system to monitor normal device operation
- Suitable for the use of 3.5 to 10 lead ECG
- Internal memory of more than 300 hours to store ECG data and events
- With integrated thermal printer
- Integrated automatic printing function for before and after discharge
- Includes manual, ADV, and AED modes
- In accordance with the accuracy requirements of ANSI/AAMI SP10:2002 and EN1060-4:2004
- AED system in accordance with ERC 2015
- 2-year quality warranty
Technical specifications
- Classification: IXP4
- Available modes: manual, consultation (ADV) or AED
- Waveform: biphasic truncated exponential (BTE), with HiCAP technology (large storage capacitor)
- Energy interval: between 1 and 230 J
- Synchronized cardioversion discharge time: < 50 milliseconds from the start of the ECG "R" wave
- Printing: manual or automatic (in automatic mode, it is activated with the energy charge and continues for 10 seconds after discharge)
- Printer type: integrated thermal on 3 channels for traces, documentation, events, and HR/SpO2/NIBP values
- Paper speed: 5, 10, 25, or 50 mm/s
- Paper width: 58 mm
- Storage capacity: up to 30 records of a maximum of 1' duration in each file
- Screen: High-resolution 7-inch 800 x 480 pixel LCD TFT with 3, 6, or 12 lead simultaneous ECG capability. Plethysmographic waveform with SpO2 sensor
- Information displayed on screen: operational data, ECG waveform, SpO2 values, NIBP values, heart rate, alarms, battery status
- ECG band: 0.5 - 120 Hz (-3 db) with deactivated filters
- CMRR ECG: > 95 dB
- ECG input impedance: > 20 Ohm
- ECG cable: 5-wire ECG cable (I, II, III, aVL, aVF, aVR, V)
- ECG amplitude: 2.5, 5, 10, 20, and 40 mm/mV with patient cable; automatic with paddles
- ECG speed: 5, 10, 25, 50 mm/s
- ECG filters: network filter (50/60 Hz) and filter for muscle tremors
- ECG frequency range: 20 - 300 bpm (~ 2%), digital reading by the screen
- ECG alarm: maximum heart rate of 250 bpm, minimum of 20 bpm. Adjustable parameters
- Error alert due to ECG cable disconnection
- Diagnostic mode
- Data memory: 4 GB (capacity for more than 300 hours of ECG data and events)
- Customizable ECG parameter view
- Paddles: reusable, for adult and pediatric patients. With charge/discharge control on the paddles themselves (manual mode)
- Systolic pressure interval: for adults, from 40 to 260 mmHg; for children, from 40 to 160 mmHg; for neonates, from 40 to 130 mmHg
- PAM (mean arterial pressure) interval: for adults, from 26 to 220 mmHg; for children, from 26 to 133 mmHg; for neonates, from 26 to 110 mmHg
- Diastolic pressure interval: for adults, from 20 to 200 mmHg; for children, from 20 to 120 mmHg; for neonates, from 20 to 100 mmHg
- Initial inflation pressure: for adults, 160 mmHg (preset); for children, 120 mmHg (preset); for neonates, 90 mmHg (preset)
- Subsequent inflation pressure: for adults, previous systolic of +30 mmHg; for children, previous systolic of +30 mmHg; for neonates, previous systolic of +20 mmHg
- Pressure transducer accuracy: 3 mmHg between 0 mmHg and 300 mmHg with temperatures between - 5 °C and 46 °C
- Maximum inflation time: 75 seconds
- Maximum pressure reading time: for adults, 130 seconds; for adults in motion, 120 seconds; for pediatric patients, 90 seconds; for neonate patients, 75 seconds
- Safety override for blood pressure measurement: for adults and children, 300 mmHg inflated or 180 seconds at 15 mmHg deflated; for neonates, 150 mmHg or 90 seconds at 5 mmHg deflated.
- Heart rate interval: from 30 to 220 BPM
- Heart rate accuracy: ± 2% or ± 3 BPM, whichever is more appropriate for the reading
- Software: multilingual voice and texts
- Impedance: compensated, from 25 to 200 Ohm
- Charging time: 6 seconds at 230J (with fully charged battery)
- AED energy: fixed at 200 J
- AED protocol: ERC 2015 CPR Guidelines, with voice and messages
- AED rhythms: VF with amplitude > 0.15 mV and VT with rhythm >150 bpm
- AED sensitivity: defibrillable VF rhythm > 95%, defibrillable VT rhythm > 75%
- AED specificity: according to ERC 2015; normal sinus rhythm > 99%; asystole and other non-defibrillable rhythms > 95%
- Energy range in manual mode: 1 - 230 J (from 1 to 10 J in steps of 1 J; from 10 to 230 J in steps of 10 J)
- Commands in manual mode: multifunction command, charge and discharge button directly on the front panel
- Modes in manual configuration: synchronous and asynchronous mode
- External pacemaker type: rectangular wave
- Pacemaker usage mode: fixed, on demand
- Pacemaker pulse frequency: 30 ppm to 250 ppm (adjustable in steps of 5 ppm)
- Pacemaker pulse duration: 22.5 ms
- Pacemaker current pulse: 0 to 150 mA (adjustable in step of 5 mA)
- External pacemaker amplitude: 150 V maximum
- Power supply: AC 100-240 VAC, 50/60 Hz
- Autonomy: > 5 hours
- Charging time: maximum 3 hours
- Duration: 150 shocks at 230 J (with fully charged battery)
- Operating conditions: from 5°C to 46°C, from 10% to 95% (no condensation)
- Storage conditions: from -20°C to 50°C, from 15% to 95% (no condensation)
- Impedance: type CF for ECG, type BF for defibrillation
- Dimensions: 369 x 240 x 340 mm
- Weight: 5.5 kg (with battery)
- Warranty: 2 years
Standard accessories (included)
- User manual
- AC power connection cable
- 1 Roll of printer paper
- 15 V - 3.2 Ah lithium battery
- 12-channel ECG cable (Ref. 1090DA-RLCP12)
- Disposable electrodes for adults
- Pacemaker module
Optional accessories (not included and at an additional cost)
- Transport bag (Ref. 1090DA-RLBT)
- Spare battery (Ref. 1090DA-RLBAT)
- Internal defibrillation paddles
- Pack of 10 thermal paper rolls 58 mm
- Disposable pediatric electrodes
- Module for SpO2 measurement
- Adult SpO2 sensor (Ref. 1090DA-RLSSA)
- Pediatric SpO2 sensor (Ref. 1090DA-RLSSP)
- 12V connection cable (cigarette lighter socket in vehicles)
- 10-wire ECG cable (I, II, III, aVL, aVF, aVR, V1.....V6)
- Module for blood pressure measurement
- Conductive gel
- Adult cuff
- Pediatric cuff
Its measurement systems have been configured according to the standards set by various directives in terms of medical accuracy, so the accuracy and reliability of its readings are guaranteed. Likewise, its automatic external defibrillation modality adheres to the recommendations specified in 2015 by the European Resuscitation Council. On the other hand, its monitoring systems are equipped with innovative software that allows storing up to 300 hours of ECG reading and automatically controls the device's pressure, thus ensuring patient safety during the measurement process. For all these reasons and the 2-year warranty it offers to the user, the Rescue Life 7 has positioned itself in the market as one of the most versatile, economical, and effective options for defibrillation.
General characteristics
- Robust and resistant device, designed for intense activity environments
- Ergonomic, intuitive, and easy-to-use design
- Reduced weight for comfortable transportation
- Illuminated buttons for better visibility
- Materials and finishes of the highest quality
- Internal self-test system with results printing to check the status of the equipment
- Up to 5 hours of autonomy in case of continuous monitoring
- Easily configurable and customizable operation
- Automatic detection of the ECG signal in diagnostic and monitoring modes
- Includes reusable defibrillation paddles and single-use adult electrodes
- Limited maximum inflation thanks to internal protection software to ensure patient safety
- Equipped with an additional redundant safety system to monitor normal device operation
- Suitable for the use of 3.5 to 10 lead ECG
- Internal memory of more than 300 hours to store ECG data and events
- With integrated thermal printer
- Integrated automatic printing function for before and after discharge
- Includes manual, ADV, and AED modes
- In accordance with the accuracy requirements of ANSI/AAMI SP10:2002 and EN1060-4:2004
- AED system in accordance with ERC 2015
- 2-year quality warranty
Technical specifications
- Classification: IXP4
- Available modes: manual, consultation (ADV) or AED
- Waveform: biphasic truncated exponential (BTE), with HiCAP technology (large storage capacitor)
- Energy interval: between 1 and 230 J
- Synchronized cardioversion discharge time: < 50 milliseconds from the start of the ECG "R" wave
- Printing: manual or automatic (in automatic mode, it is activated with the energy charge and continues for 10 seconds after discharge)
- Printer type: integrated thermal on 3 channels for traces, documentation, events, and HR/SpO2/NIBP values
- Paper speed: 5, 10, 25, or 50 mm/s
- Paper width: 58 mm
- Storage capacity: up to 30 records of a maximum of 1' duration in each file
- Screen: High-resolution 7-inch 800 x 480 pixel LCD TFT with 3, 6, or 12 lead simultaneous ECG capability. Plethysmographic waveform with SpO2 sensor
- Information displayed on screen: operational data, ECG waveform, SpO2 values, NIBP values, heart rate, alarms, battery status
- ECG band: 0.5 - 120 Hz (-3 db) with deactivated filters
- CMRR ECG: > 95 dB
- ECG input impedance: > 20 Ohm
- ECG cable: 5-wire ECG cable (I, II, III, aVL, aVF, aVR, V)
- ECG amplitude: 2.5, 5, 10, 20, and 40 mm/mV with patient cable; automatic with paddles
- ECG speed: 5, 10, 25, 50 mm/s
- ECG filters: network filter (50/60 Hz) and filter for muscle tremors
- ECG frequency range: 20 - 300 bpm (~ 2%), digital reading by the screen
- ECG alarm: maximum heart rate of 250 bpm, minimum of 20 bpm. Adjustable parameters
- Error alert due to ECG cable disconnection
- Diagnostic mode
- Data memory: 4 GB (capacity for more than 300 hours of ECG data and events)
- Customizable ECG parameter view
- Paddles: reusable, for adult and pediatric patients. With charge/discharge control on the paddles themselves (manual mode)
- Systolic pressure interval: for adults, from 40 to 260 mmHg; for children, from 40 to 160 mmHg; for neonates, from 40 to 130 mmHg
- PAM (mean arterial pressure) interval: for adults, from 26 to 220 mmHg; for children, from 26 to 133 mmHg; for neonates, from 26 to 110 mmHg
- Diastolic pressure interval: for adults, from 20 to 200 mmHg; for children, from 20 to 120 mmHg; for neonates, from 20 to 100 mmHg
- Initial inflation pressure: for adults, 160 mmHg (preset); for children, 120 mmHg (preset); for neonates, 90 mmHg (preset)
- Subsequent inflation pressure: for adults, previous systolic of +30 mmHg; for children, previous systolic of +30 mmHg; for neonates, previous systolic of +20 mmHg
- Pressure transducer accuracy: 3 mmHg between 0 mmHg and 300 mmHg with temperatures between - 5 °C and 46 °C
- Maximum inflation time: 75 seconds
- Maximum pressure reading time: for adults, 130 seconds; for adults in motion, 120 seconds; for pediatric patients, 90 seconds; for neonate patients, 75 seconds
- Safety override for blood pressure measurement: for adults and children, 300 mmHg inflated or 180 seconds at 15 mmHg deflated; for neonates, 150 mmHg or 90 seconds at 5 mmHg deflated.
- Heart rate interval: from 30 to 220 BPM
- Heart rate accuracy: ± 2% or ± 3 BPM, whichever is more appropriate for the reading
- Software: multilingual voice and texts
- Impedance: compensated, from 25 to 200 Ohm
- Charging time: 6 seconds at 230J (with fully charged battery)
- AED energy: fixed at 200 J
- AED protocol: ERC 2015 CPR Guidelines, with voice and messages
- AED rhythms: VF with amplitude > 0.15 mV and VT with rhythm >150 bpm
- AED sensitivity: defibrillable VF rhythm > 95%, defibrillable VT rhythm > 75%
- AED specificity: according to ERC 2015; normal sinus rhythm > 99%; asystole and other non-defibrillable rhythms > 95%
- Energy range in manual mode: 1 - 230 J (from 1 to 10 J in steps of 1 J; from 10 to 230 J in steps of 10 J)
- Commands in manual mode: multifunction command, charge and discharge button directly on the front panel
- Modes in manual configuration: synchronous and asynchronous mode
- External pacemaker type: rectangular wave
- Pacemaker usage mode: fixed, on demand
- Pacemaker pulse frequency: 30 ppm to 250 ppm (adjustable in steps of 5 ppm)
- Pacemaker pulse duration: 22.5 ms
- Pacemaker current pulse: 0 to 150 mA (adjustable in step of 5 mA)
- External pacemaker amplitude: 150 V maximum
- Power supply: AC 100-240 VAC, 50/60 Hz
- Autonomy: > 5 hours
- Charging time: maximum 3 hours
- Duration: 150 shocks at 230 J (with fully charged battery)
- Operating conditions: from 5°C to 46°C, from 10% to 95% (no condensation)
- Storage conditions: from -20°C to 50°C, from 15% to 95% (no condensation)
- Impedance: type CF for ECG, type BF for defibrillation
- Dimensions: 369 x 240 x 340 mm
- Weight: 5.5 kg (with battery)
- Warranty: 2 years
Standard accessories (included)
- User manual
- AC power connection cable
- 1 Roll of printer paper
- 15 V - 3.2 Ah lithium battery
- 12-channel ECG cable (Ref. 1090DA-RLCP12)
- Disposable electrodes for adults
- Pacemaker module
Optional accessories (not included and at an additional cost)
- Transport bag (Ref. 1090DA-RLBT)
- Spare battery (Ref. 1090DA-RLBAT)
- Internal defibrillation paddles
- Pack of 10 thermal paper rolls 58 mm
- Disposable pediatric electrodes
- Module for SpO2 measurement
- Adult SpO2 sensor (Ref. 1090DA-RLSSA)
- Pediatric SpO2 sensor (Ref. 1090DA-RLSSP)
- 12V connection cable (cigarette lighter socket in vehicles)
- 10-wire ECG cable (I, II, III, aVL, aVF, aVR, V1.....V6)
- Module for blood pressure measurement
- Conductive gel
- Adult cuff
- Pediatric cuff