Reference. 1090DA-MDI6PRO
i6 Pro Defibrillator-Monitor with pacemaker and printer (5 channel ECG, Resp, SpO2, NIBP, Temp, EtCO2)
Sanitary device designed for monitoring vital signs and defibrillation. With 5 ECG channels, printer, pacemaker and systems for measuring body temperature, blood pressure, exhaled carbon dioxide and blood oxygen saturation level.
Personal advice
Description
The i6 Pro is a milestone in the field of healthcare due to its innovative design and multiple features. Its operating system is capable of measuring parameters as varied as body temperature, blood pressure, blood oxygen saturation level, and exhaled carbon dioxide level, allowing for precise control of the patient's vital signs. All of this is combined with a state-of-the-art defibrillator capable of delivering shocks in AED mode and manual mode, both synchronously and asynchronously. Due to the advantages it offers over other models on the market, it is ideal for all types of professional environments, whether ambulances, emergency triages, or intensive care units.
General Features
- Large size color HD screen for clear visualization of parameters
- Front button user interface to facilitate access to main functions
- Compact design with integrated handle for comfortable and practical transport
- Attached thermal printer allows for printing results obtained during monitoring
- Integrated pediatric defibrillator paddles within the adult ones, with energy selection, discharge, and charge buttons
- 3-step defibrillation compatible with external, internal, and disposable electrodes
- Exportable self-test option to PC and printable
- Customizable alarms for all monitoring parameters
- Incorporates hooks for attachment to bed rails and tracks
General Technical Specifications
- Waveform: truncated exponential biphasic, automatically adjusted to patient impedance
- Display screen: 7" HD color LCD (TFT) screen with a resolution of 800 x 480 pixels
- Power supply: 100 - 240 V, 50/60 Hz
- Battery: rechargeable internal lithium battery with 5 hours/+100 discharges autonomy
- Battery charging time: less than 3 hours
- Defibrillation modes: manual asynchronous, manual synchronous, AED
- Operating modes: AED, monitoring, pacemaker, manual defibrillation
- Charging time: 200 J (in less than 5 seconds), 360 J (in less than 8 seconds)
- Degree of protection: IP54
- Operating temperature: 0 - 50°C
- Storage temperature: -30°C - 70°C
- Dimensions: 290 x 208 x 297 mm
- Weight: 5.8 kg
AED Mode Specifications
- CPR assistance protocol included
- Assistance adjusted to the latest recommendations of the AHA and ERC
- Acoustic and visual guide indicated to be able to discharge effectively
- Discharge through disposable defibrillation electrodes
Monitoring Mode Specifications
- 3 curve screen monitoring
Pacemaker Mode Specifications
- Simple and quick activation thanks to the mode selection wheel
- Discharge through defibrillation electrodes
- Fixed and on-demand modes
- Configurable stimulation frequency between 40 and 170 bpm (±1.5%)
- Configurable output current, from 0 to 200 mA (±5% or ±5mA, whichever is greater)
Manual Defibrillation Mode Specifications
- Selectable energy steps of 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 30, 50, 70, 100, 150, 170, 200, 300, and 360 J
- Discharge through paddles or defibrillation electrodes
ECG Specifications
- 5-lead cable (5 electrodes/7 channels): I, II, III, aVR, aVL, AVF, V
- Sweep speed: 50, 25, 12.5, 6.25 mm/s
- Therapy mode bandwidth: 1 - 20 Hz
- Monitoring mode bandwidth: 0.5 - 40 Hz
- Diagnostic mode bandwidth: 0.05 - 150 Hz
- Common mode rejection: > 105 dB
- Powerline frequency rejection: ≥ 20 dB
- Baseline recovery after defibrillation: < 5 s
- HR measurement range: 15 - 300 bpm (adult patients), 15 - 350 bpm (pediatric patients)
- HR accuracy: ± 1 bpm
- Pacemaker detection: displayed as a marker on the ECG
- Pacemaker filtering: inhibition of stimulation signals according to (IEC 60601-2-27 standard)
SpO2 Specifications
- Measurement range: 0% - 100%
- Accuracy: ± 2 %
- Recovery after defibrillation: < 5 s
- Pulse frequency measurement range: 30 – 240 bpm
- Pulse frequency accuracy: ±3 bpm
- Pulse frequency resolution: 1 bpm
- Adhered standard: ISO 80601-2-61
Resp Specifications
- Measurement range: 0 - 120 rpm
- Accuracy: ± 2 rpm or ± 2 %
- Resolution: 1 rpm
- Apnea alarm: 10s, 15s, 20s, 25s, 30s, 35s, 40s
Temp Specifications
- Measurement range: 0°C - 50°C
- Accuracy: ± 0.1°C
- Resolution: 0.1°C
- Recovery after defibrillation: < 5 s
PANI Specifications
- Measurement modes: manual, automatic, and continuous
- Automatic measurement intervals: 1, 2, 3, 4, 10, 15, 20, 30, 60, 90, 120, 180, 240, 480 min
- Measurement range: 0 - 300 mmHg
- Accuracy: ± 3 mmHg
- Resolution: 1 mmHg
- Recovery after defibrillation: < 5 s
- Protection: against overpressure
- Adhered standard: IEC 80601-2-30
EtCO2 Specifications
- Measurement mode: continuous mainstream
- Measurement range: 0 - 99 mmHg
- Accuracy: ±2 mmHg (0 - 40 mmHg), ±5% (41 - 76 mmHg) and ±10% (77 - 99 mmHg)
- Recovery after defibrillation: < 5 s
Standard Accessories (included)
- Power cable
- Rechargeable battery
- Attachment hooks
- Pacemaker
- External paddles (for adult and pediatric patients)
- Defibrillation electrode cable
- Defibrillation electrodes (for adult and pediatric patients)
- Printer thermal paper
- 5-lead ECG cable
- Standard size adult PANI extension cable and cuff
- Adult SpO2 sensor
- Skin temperature probe
- Mainstream capnography module
Optional Accessories (not included and at an additional cost)
- Carry bag
- Rolling stand
- Stop cart
- PC software for patient and exam management (with real-time visualization)
- CPR quality sensor
- Internal paddles (for adult, pediatric, or neonatal patients)
- Defibrillation electrodes (for adult, pediatric, or neonatal patients)
- 3-channel ECG cable 1090DA-CP3I2I6)
- Adult clip type SpO2 sensor (Ref. 1090DA-OXAI6)
- Adult thimble type SpO2 sensor (Ref. 1090DA-OXISAI6)
- Small adult PANI cuff (Ref. 1090DA-MANAPI6)
- Standard adult PANI cuff (Ref. 1090DA-MANAI6)
- Large adult PANI cuff (Ref. 1090DA-MANAGI6)
- Adult CO2 adapter (Ref. 1090DA-ADPCO2A)
- Pediatric CO2 adapter
General Features
- Large size color HD screen for clear visualization of parameters
- Front button user interface to facilitate access to main functions
- Compact design with integrated handle for comfortable and practical transport
- Attached thermal printer allows for printing results obtained during monitoring
- Integrated pediatric defibrillator paddles within the adult ones, with energy selection, discharge, and charge buttons
- 3-step defibrillation compatible with external, internal, and disposable electrodes
- Exportable self-test option to PC and printable
- Customizable alarms for all monitoring parameters
- Incorporates hooks for attachment to bed rails and tracks
General Technical Specifications
- Waveform: truncated exponential biphasic, automatically adjusted to patient impedance
- Display screen: 7" HD color LCD (TFT) screen with a resolution of 800 x 480 pixels
- Power supply: 100 - 240 V, 50/60 Hz
- Battery: rechargeable internal lithium battery with 5 hours/+100 discharges autonomy
- Battery charging time: less than 3 hours
- Defibrillation modes: manual asynchronous, manual synchronous, AED
- Operating modes: AED, monitoring, pacemaker, manual defibrillation
- Charging time: 200 J (in less than 5 seconds), 360 J (in less than 8 seconds)
- Degree of protection: IP54
- Operating temperature: 0 - 50°C
- Storage temperature: -30°C - 70°C
- Dimensions: 290 x 208 x 297 mm
- Weight: 5.8 kg
AED Mode Specifications
- CPR assistance protocol included
- Assistance adjusted to the latest recommendations of the AHA and ERC
- Acoustic and visual guide indicated to be able to discharge effectively
- Discharge through disposable defibrillation electrodes
Monitoring Mode Specifications
- 3 curve screen monitoring
Pacemaker Mode Specifications
- Simple and quick activation thanks to the mode selection wheel
- Discharge through defibrillation electrodes
- Fixed and on-demand modes
- Configurable stimulation frequency between 40 and 170 bpm (±1.5%)
- Configurable output current, from 0 to 200 mA (±5% or ±5mA, whichever is greater)
Manual Defibrillation Mode Specifications
- Selectable energy steps of 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 30, 50, 70, 100, 150, 170, 200, 300, and 360 J
- Discharge through paddles or defibrillation electrodes
ECG Specifications
- 5-lead cable (5 electrodes/7 channels): I, II, III, aVR, aVL, AVF, V
- Sweep speed: 50, 25, 12.5, 6.25 mm/s
- Therapy mode bandwidth: 1 - 20 Hz
- Monitoring mode bandwidth: 0.5 - 40 Hz
- Diagnostic mode bandwidth: 0.05 - 150 Hz
- Common mode rejection: > 105 dB
- Powerline frequency rejection: ≥ 20 dB
- Baseline recovery after defibrillation: < 5 s
- HR measurement range: 15 - 300 bpm (adult patients), 15 - 350 bpm (pediatric patients)
- HR accuracy: ± 1 bpm
- Pacemaker detection: displayed as a marker on the ECG
- Pacemaker filtering: inhibition of stimulation signals according to (IEC 60601-2-27 standard)
SpO2 Specifications
- Measurement range: 0% - 100%
- Accuracy: ± 2 %
- Recovery after defibrillation: < 5 s
- Pulse frequency measurement range: 30 – 240 bpm
- Pulse frequency accuracy: ±3 bpm
- Pulse frequency resolution: 1 bpm
- Adhered standard: ISO 80601-2-61
Resp Specifications
- Measurement range: 0 - 120 rpm
- Accuracy: ± 2 rpm or ± 2 %
- Resolution: 1 rpm
- Apnea alarm: 10s, 15s, 20s, 25s, 30s, 35s, 40s
Temp Specifications
- Measurement range: 0°C - 50°C
- Accuracy: ± 0.1°C
- Resolution: 0.1°C
- Recovery after defibrillation: < 5 s
PANI Specifications
- Measurement modes: manual, automatic, and continuous
- Automatic measurement intervals: 1, 2, 3, 4, 10, 15, 20, 30, 60, 90, 120, 180, 240, 480 min
- Measurement range: 0 - 300 mmHg
- Accuracy: ± 3 mmHg
- Resolution: 1 mmHg
- Recovery after defibrillation: < 5 s
- Protection: against overpressure
- Adhered standard: IEC 80601-2-30
EtCO2 Specifications
- Measurement mode: continuous mainstream
- Measurement range: 0 - 99 mmHg
- Accuracy: ±2 mmHg (0 - 40 mmHg), ±5% (41 - 76 mmHg) and ±10% (77 - 99 mmHg)
- Recovery after defibrillation: < 5 s
Standard Accessories (included)
- Power cable
- Rechargeable battery
- Attachment hooks
- Pacemaker
- External paddles (for adult and pediatric patients)
- Defibrillation electrode cable
- Defibrillation electrodes (for adult and pediatric patients)
- Printer thermal paper
- 5-lead ECG cable
- Standard size adult PANI extension cable and cuff
- Adult SpO2 sensor
- Skin temperature probe
- Mainstream capnography module
Optional Accessories (not included and at an additional cost)
- Carry bag
- Rolling stand
- Stop cart
- PC software for patient and exam management (with real-time visualization)
- CPR quality sensor
- Internal paddles (for adult, pediatric, or neonatal patients)
- Defibrillation electrodes (for adult, pediatric, or neonatal patients)
- 3-channel ECG cable 1090DA-CP3I2I6)
- Adult clip type SpO2 sensor (Ref. 1090DA-OXAI6)
- Adult thimble type SpO2 sensor (Ref. 1090DA-OXISAI6)
- Small adult PANI cuff (Ref. 1090DA-MANAPI6)
- Standard adult PANI cuff (Ref. 1090DA-MANAI6)
- Large adult PANI cuff (Ref. 1090DA-MANAGI6)
- Adult CO2 adapter (Ref. 1090DA-ADPCO2A)
- Pediatric CO2 adapter