High-level disinfectant Anioxyde 1000 LD. 5 L jug.
High-level disinfectant based on the extemporaneous production of peracetic acid designed for cleaning medical equipment and endoscopic devices. Supplied in a five-liter jug with an integrated activator.
Personal advice
Description
Anioxyde 1000 DL is a high-level disinfectant designed for cleaning surgical equipment, endoscopy devices, and thermosensitive equipment after use. It is a product based on the extemporaneous production of peracetic acid that allows the elimination of all types of pathogens from medical material, including viruses, bacteria, yeasts, fungi, and mycobacteria. With an action time not exceeding 5 minutes, it offers a safe, convenient, and reliable solution for disinfecting medical equipment in a professional environment.
General Features
- High-level disinfectant with patented formula and reduced reaction time
- Based on the extemporaneous production of peracetic acid according to the PHERA® system
- Superior disinfecting power, with proven efficacy at 1000 ppm of peracetic acid
- Highly compatible, it can be safely used on a wide range of materials
- Supplied with integrated activator liquid in the package for convenient, simple, and intuitive use
- Completely free of aldehydes and free of acetic acid vapor, it ensures greater safety
- Suitable for use on medical equipment, endoscopy devices, and thermosensitive equipment
- It is recommended to periodically check its effectiveness with compatible reactive strips (not included and at an additional cost)
Technical Specifications
- Composition: extemporaneous production of peracetic acid from acetylcaprolactam (PHERA system); Anioxyde 1000 LD contains 3% hydrogen peroxide
- Concentration: 2000 ppm of peracetic acid (when activated); 1000 ppm (maximum threshold detected by reactive strips)
- Solution color (activated): pink
- Storage temperature: 5ºC - 25ºC
- Format: 5 L jug
- Shelf life before use: 24 months
Regulations and certifications
Healthcare product intended for professional use only
Indications
Anioxyde 1000 DL is indicated for multiple medical devices, including surgical equipment, endoscopy devices, and color-sensitive equipment.
How to use
- Pour the contents of the activator (39.1 ml bottle) into the generator (5 L jug), mix the solution and pour it over a bucket or immersion bath.
- Wait at least 30 minutes for the product to fully activate and ensure the described biocidal effect.
- Thoroughly clean and rinse the medical product with a detergent or a predesinfectant before submerging it in the bath.
- Check the level of peracetic acid with Anioxyde 1000 DL reactive strips (not included and at an additional cost) every time you need to start disinfection, interrupt the process or do it continuously for more than 4 hours.
- Do not use the disinfectant for more than 14 days or a maximum of 7 days if you are in a territory regulated by French legislation
Instructions for use
- Clean the medical product with a specific detergent or predesinfectant before submerging it in the solution. In the case of endoscopy instruments, thoroughly brush the channels.
- Pour the activated solution and submerge the instruments in it. During the immersion process, keep the bath covered. In the case of endoscopy products, recirculate the solution through the inside of the ducts.
- Rinse with plenty of sterile or filtered water (0.2 μm) to remove any trace of the product. In the case of endoscopes, make sure to rinse both externally and internally.
- Dry with a single-use towel and keep the medical device as aseptic as possible until use.
General Features
- High-level disinfectant with patented formula and reduced reaction time
- Based on the extemporaneous production of peracetic acid according to the PHERA® system
- Superior disinfecting power, with proven efficacy at 1000 ppm of peracetic acid
- Highly compatible, it can be safely used on a wide range of materials
- Supplied with integrated activator liquid in the package for convenient, simple, and intuitive use
- Completely free of aldehydes and free of acetic acid vapor, it ensures greater safety
- Suitable for use on medical equipment, endoscopy devices, and thermosensitive equipment
- It is recommended to periodically check its effectiveness with compatible reactive strips (not included and at an additional cost)
Technical Specifications
- Composition: extemporaneous production of peracetic acid from acetylcaprolactam (PHERA system); Anioxyde 1000 LD contains 3% hydrogen peroxide
- Concentration: 2000 ppm of peracetic acid (when activated); 1000 ppm (maximum threshold detected by reactive strips)
- Solution color (activated): pink
- Storage temperature: 5ºC - 25ºC
- Format: 5 L jug
- Shelf life before use: 24 months
Regulations and certifications
Healthcare product intended for professional use only
Indications
Anioxyde 1000 DL is indicated for multiple medical devices, including surgical equipment, endoscopy devices, and color-sensitive equipment.
How to use
- Pour the contents of the activator (39.1 ml bottle) into the generator (5 L jug), mix the solution and pour it over a bucket or immersion bath.
- Wait at least 30 minutes for the product to fully activate and ensure the described biocidal effect.
- Thoroughly clean and rinse the medical product with a detergent or a predesinfectant before submerging it in the bath.
- Check the level of peracetic acid with Anioxyde 1000 DL reactive strips (not included and at an additional cost) every time you need to start disinfection, interrupt the process or do it continuously for more than 4 hours.
- Do not use the disinfectant for more than 14 days or a maximum of 7 days if you are in a territory regulated by French legislation
Instructions for use
- Clean the medical product with a specific detergent or predesinfectant before submerging it in the solution. In the case of endoscopy instruments, thoroughly brush the channels.
- Pour the activated solution and submerge the instruments in it. During the immersion process, keep the bath covered. In the case of endoscopy products, recirculate the solution through the inside of the ducts.
- Rinse with plenty of sterile or filtered water (0.2 μm) to remove any trace of the product. In the case of endoscopes, make sure to rinse both externally and internally.
- Dry with a single-use towel and keep the medical device as aseptic as possible until use.