Reference. 400129517
Fetal monitor for twins FC1400
Fetal monitorfor twins to measure fetal heart rate (FHR), the degree of uterine contraction material (UA: uterine activity) and fetal movements (FM).
Personal advice
Description
Fetal monitor for twins to measure fetal heart rate (FHR), uterine contraction material degree (UA: uterine activity) and fetal movements (FM).
Data display:
- 7 "color TFT LCD touch screen (800x480)
- 2 display modes: graphic and text modes
- 72 hours of memory capacity
Extreme data access and accuracy
- Wide and high precision detection area
- Easy scrolling function on screen
- 1 MHz watertight probes to minimize disruption of FHR waveforms even if the fetus moves
Printing
- CTG interpretation report
- Both standard size and A4 paper can be used
- Compatible with normal fax paper
Other advantages
- PC compatible
- Possibility of incorporating 2-hour internal battery (optional accessory at additional cost)
- Power adapter 100-240 V, 50-60 Hz
- Multilingual internal software: GB, FR, IT, ES, PT, DE, PL, RO, RU, CZ, HU, BG, TR, KR, CN.
Recommended after week 30.
Technical specifications
• Dimensions: 296 x 97.5 x h 305.5 mm - Approx. 2.9 kg
• Display: 7 "widescreen TFT LCD (800x480)
• Thermal matrix printer: printing speed: 1, 2, 3 cm / min (real time), paper feed function
• Power input:
- 100-240 V, 1.5-0.7 A, 50-60 Hz
- Output: +18 V = 2.8 A
• External link: LAN, Wi-Fi, USB memory
• Fetal heart rate
- input signal: pulsed Doppler ultrasound
- ultrasound frequency: 1.0 Mhz, 975 Khz
- ultrasound power: <10 mW / cm2
- FCF detection method: autocorrelation
- FCF range: 50-210 bpm ± 1 bpm (120-160)
• Fetal movement measurement: detection source: pulsed Doppler ultrasound, event marker
• Uterine contraction
- Input source: external transducer with load cell
- Reference control: one-touch switch, automatic zeroing
- Measurement range: 0-99
• Automatic CTG analysis
- Average initial FCF
- Number of UC
- Number of acceleration
- Number of deceleration
- Late deceleration
- Early deceleration
- Variable deceleration
- High episode
- Low episode
- Short term variability
- Signal loss
Data display:
- 7 "color TFT LCD touch screen (800x480)
- 2 display modes: graphic and text modes
- 72 hours of memory capacity
Extreme data access and accuracy
- Wide and high precision detection area
- Easy scrolling function on screen
- 1 MHz watertight probes to minimize disruption of FHR waveforms even if the fetus moves
Printing
- CTG interpretation report
- Both standard size and A4 paper can be used
- Compatible with normal fax paper
Other advantages
- PC compatible
- Possibility of incorporating 2-hour internal battery (optional accessory at additional cost)
- Power adapter 100-240 V, 50-60 Hz
- Multilingual internal software: GB, FR, IT, ES, PT, DE, PL, RO, RU, CZ, HU, BG, TR, KR, CN.
Recommended after week 30.
Technical specifications
• Dimensions: 296 x 97.5 x h 305.5 mm - Approx. 2.9 kg
• Display: 7 "widescreen TFT LCD (800x480)
• Thermal matrix printer: printing speed: 1, 2, 3 cm / min (real time), paper feed function
• Power input:
- 100-240 V, 1.5-0.7 A, 50-60 Hz
- Output: +18 V = 2.8 A
• External link: LAN, Wi-Fi, USB memory
• Fetal heart rate
- input signal: pulsed Doppler ultrasound
- ultrasound frequency: 1.0 Mhz, 975 Khz
- ultrasound power: <10 mW / cm2
- FCF detection method: autocorrelation
- FCF range: 50-210 bpm ± 1 bpm (120-160)
• Fetal movement measurement: detection source: pulsed Doppler ultrasound, event marker
• Uterine contraction
- Input source: external transducer with load cell
- Reference control: one-touch switch, automatic zeroing
- Measurement range: 0-99
• Automatic CTG analysis
- Average initial FCF
- Number of UC
- Number of acceleration
- Number of deceleration
- Late deceleration
- Early deceleration
- Variable deceleration
- High episode
- Low episode
- Short term variability
- Signal loss