Reference. 10155320555
Eurovac® H-50 electric surgical vacuum, 80 L/min
Electric vacuum cleaner equipped with a 4-liter jar and equipped with a powerful suction system capable of absorbing up to 80 liters of liquid per minute. Specially designed to aspirate body fluids during surgical intervention.
Description
The Eurovac® H-50 electric aspirator allows healthcare professionals to easily and comfortably aspirate body fluids during surgery, thereby helping to keep the operating field clean and minimizing the risk of cross-infections. Its design includes a housing made of high-quality, durable materials to ensure its longevity, and it has a state-of-the-art absorption system capable of suctioning large amounts of liquid in a short time, making it one of the most efficient and economical options on the market.
Features
- Made of high-quality ABS to resist impacts and scratches
- Oil-free vacuum pump with long-lasting piston design that requires no maintenance
- High vacuum gauge (0-100 kPa/0-760 mmHg) with great visibility (Ø 67 mm)
- Stable and highly accurate vacuum regulation knob
- Collection jar made of polycarbonate with a maximum capacity of 4 liters (scale up to 3500 mL)
- Collection container equipped with a safety valve for overfilling
- Availability of supports compatible with the main disposable canisters
- It has a hydrophobic double spike bacteria filter made of polytetrafluoroethylene
- Includes a 3-meter power cord
- Incorporates a power on and off switch to facilitate suction control
- It includes a Yankauer cannula and a 2-meter PVC suction tube (8 x 13 mm)
Technical specifications
- Dimensions: 960 x 430 x 340 mm
- Weight: 25 kg
- Maximum pump flow (±5% measured at 230 V / 60 Hz): 80 L/min
- Maximum vacuum (±5% measured at 230 V / 60 Hz): 90 kPa / 900 mbar / 675 mmHg
- Noise level: 50 ± 1.5 dB (AS) / 1 m
- Power: 250 W
- Intensity: 1.3 A
- Number of jars: 1
- Jar capacity: 4 L
- Voltage: 200 – 240 VAC (50-60 Hz) / Available 100 – 120 VAC
- Filter retention efficiency: 99% particles; 99.99% bacteria
- Storage temperature: from -40 °C to 70 °C / from -40 °F to 158 °F
- Operating temperature: from 7 °C to 40 °C / from 44 °F to 104 °F
Certificates
- EN ISO 19054:200 (collection jar support)
- ISO 10079-1:2015
- 93/42/EEC. Categorized as a Class IIa medical device
- ISO IEC 60601-1:2006. Classified as Class I, Type BF, IP22 product
Optional accessories (not included and with additional cost)
- PC4 4L polycarbonate probe washer / probe holder
- Replacement 4L polycarbonate collection jar (Ref. 10154383004)
- 4L polysulfone collection jar (Ref. 10154383014)
- 4L polycarbonate collection jar without lid
- 4L polysulfone collection jar without lid
- 4L polycarbonate collection jar lid
- 4L polysulfone collection jar lid
- Polysulfone float kit for collection jars with sealing gasket
- Electropneumatic pedal kit for on and off
- 8 x 13 mm (1 m) PVC suction tube
- 8 x 13 mm (1 m) silicone suction tube
- Replacement Yankauer cannula with 8 x 13 mm (2 m) PVC suction tube
- Exchange knob for 2 suction jars
- Replacement hydrophobic double spike bacteria filter (Ref. 10153320534)
- Replacement 3 m power cord
Features
- Made of high-quality ABS to resist impacts and scratches
- Oil-free vacuum pump with long-lasting piston design that requires no maintenance
- High vacuum gauge (0-100 kPa/0-760 mmHg) with great visibility (Ø 67 mm)
- Stable and highly accurate vacuum regulation knob
- Collection jar made of polycarbonate with a maximum capacity of 4 liters (scale up to 3500 mL)
- Collection container equipped with a safety valve for overfilling
- Availability of supports compatible with the main disposable canisters
- It has a hydrophobic double spike bacteria filter made of polytetrafluoroethylene
- Includes a 3-meter power cord
- Incorporates a power on and off switch to facilitate suction control
- It includes a Yankauer cannula and a 2-meter PVC suction tube (8 x 13 mm)
Technical specifications
- Dimensions: 960 x 430 x 340 mm
- Weight: 25 kg
- Maximum pump flow (±5% measured at 230 V / 60 Hz): 80 L/min
- Maximum vacuum (±5% measured at 230 V / 60 Hz): 90 kPa / 900 mbar / 675 mmHg
- Noise level: 50 ± 1.5 dB (AS) / 1 m
- Power: 250 W
- Intensity: 1.3 A
- Number of jars: 1
- Jar capacity: 4 L
- Voltage: 200 – 240 VAC (50-60 Hz) / Available 100 – 120 VAC
- Filter retention efficiency: 99% particles; 99.99% bacteria
- Storage temperature: from -40 °C to 70 °C / from -40 °F to 158 °F
- Operating temperature: from 7 °C to 40 °C / from 44 °F to 104 °F
Certificates
- EN ISO 19054:200 (collection jar support)
- ISO 10079-1:2015
- 93/42/EEC. Categorized as a Class IIa medical device
- ISO IEC 60601-1:2006. Classified as Class I, Type BF, IP22 product
Optional accessories (not included and with additional cost)
- PC4 4L polycarbonate probe washer / probe holder
- Replacement 4L polycarbonate collection jar (Ref. 10154383004)
- 4L polysulfone collection jar (Ref. 10154383014)
- 4L polycarbonate collection jar without lid
- 4L polysulfone collection jar without lid
- 4L polycarbonate collection jar lid
- 4L polysulfone collection jar lid
- Polysulfone float kit for collection jars with sealing gasket
- Electropneumatic pedal kit for on and off
- 8 x 13 mm (1 m) PVC suction tube
- 8 x 13 mm (1 m) silicone suction tube
- Replacement Yankauer cannula with 8 x 13 mm (2 m) PVC suction tube
- Exchange knob for 2 suction jars
- Replacement hydrophobic double spike bacteria filter (Ref. 10153320534)
- Replacement 3 m power cord