Reference. 1208TEA12
Rectangular disposable ECG electrode with solid gel and foam, 42 x 32 mm. Box of 100 units.
Single-use solid gel and polyethylene foam electrode designed for monitoring with an electrocardiogram. Supplied in a box of 100 units.
Description
Disposable electrode composed of a waterproof polyethylene flexible foam layer, a steel sensor with silver chloride coating, a water-soluble acrylic-based solid lubricant gel, and a biocompatible acrylic adhesive. Its design allows it to intercept and amplify the electrical pulses arising from the depolarization of the heart, making it very useful for monitoring cardiac activity with electrocardiogram equipment.
Technical Specifications
- Dimensions: 42 x 32 mm
- Shape: rectangular
- Shelf life: 3 years from the date of manufacture
Materials
- Support: waterproof polyethylene flexible foam
- Adhesive: biocompatible acrylic according to ISO 10993
- Sensor: stainless steel/plastic rivet coated with silver/silver chloride
- Protector: polyethylene terephthalate
- Solid gel: water-soluble acrylic-based polymer
Electrical Properties (ANSI/AAMI EC12)
- DC Offset Voltage: < 100 mV
- AC Impedance 10 Hz: < 2000 Ω
- Defibrillation overload recovery: < 100 mV, < 1 mV/s
- Combined residual instability and internal noise: < 150 µV
- 8 h trend current tolerance: < 100 mV
Biocompatibility
- ISO 10993-5: non-cytotoxic
- ISO 10993-10: not skin sensitizing
- ISO 10993-10: negative intracutaneous irritation test
Regulations and Certifications
- ISO 10993
- ISO 13485
- Regulation (EU) 2017/745, Class I medical product
Supplied in a box of 100 units.
Technical Specifications
- Dimensions: 42 x 32 mm
- Shape: rectangular
- Shelf life: 3 years from the date of manufacture
Materials
- Support: waterproof polyethylene flexible foam
- Adhesive: biocompatible acrylic according to ISO 10993
- Sensor: stainless steel/plastic rivet coated with silver/silver chloride
- Protector: polyethylene terephthalate
- Solid gel: water-soluble acrylic-based polymer
Electrical Properties (ANSI/AAMI EC12)
- DC Offset Voltage: < 100 mV
- AC Impedance 10 Hz: < 2000 Ω
- Defibrillation overload recovery: < 100 mV, < 1 mV/s
- Combined residual instability and internal noise: < 150 µV
- 8 h trend current tolerance: < 100 mV
Biocompatibility
- ISO 10993-5: non-cytotoxic
- ISO 10993-10: not skin sensitizing
- ISO 10993-10: negative intracutaneous irritation test
Regulations and Certifications
- ISO 10993
- ISO 13485
- Regulation (EU) 2017/745, Class I medical product
Supplied in a box of 100 units.